33
Lower the treadmill (see HOW TO LOWER THE
TREADMILL FOR USE on page 31). Remove the four
indicated #8 x 3/4" Screws (7), and remove the Motor
Hood (66).
Next, locate the Reed Switch (48) and the Magnet
(124) on the left side of the Pulley (54). Turn the
Pulley until the Magnet is aligned with the Reed
Switch.
Make sure that the gap between the
Magnet and the Reed Switch is about 1/8 in. (3
mm).
If necessary, loosen the indicated #8 x 3/4"
Washer Head Tek Screw (26), move the Reed Switch
slightly, and then retighten the Tek Screw. Reattach
the Hood (not shown) with the six #8 x 3/4" Screws
(not shown). Run the treadmill for a few minutes to
check for a correct speed reading.
PROBLEM: The walking belt slows when walked on
SOLUTION:
a. Use only a single-outlet surge suppressor that meets all of the specifications described on page 15.
b. If the walking belt is overtightened, treadmill perfor-
mance may decrease and the walking belt may be-
come damaged. Remove the key and
UNPLUG THE
POWER CORD
. Using the hex key, turn both idler
roller bolts counterclockwise, 1/4 of a turn. When the
walking belt is properly tightened, you should be able
to lift each edge of the walking belt 3 to 4 in. (8 to 10
cm) off the walking platform. Be careful to keep the
walking belt centered. Then, plug in the power cord,
insert the key, and run the treadmill for a few min-
utes. Repeat until the walking belt is properly tight-
ened.
c. If the walking belt still slows when walked on, please see the front cover of this manual.
PROBLEM: The walking belt is off-center or slips when walked on
SOLUTION:
a. If the walking belt is off-center, remove the key and
UNPLUG THE POWER CORD. If the walking belt
has shifted to the left,
use the hex key to turn the
left idler roller bolt clockwise 1/2 of a turn;
if the walk-
ing belt has shifted to the right,
turn the left idler
roller bolt counterclockwise 1/2 of a turn. Be careful
not to overtighten the walking belt. Plug in the power
cord, insert the key, and run the treadmill for a few
minutes. Repeat until the walking belt is centered.
Top
View
26
48
1/8 in.
54
124
7
66
7
Idler Roller Bolts
b
3–4 in.
a