MAINTENANCE AND TROUBLESHOOTING
MAINTENANCE
Regular maintenance is important for optimal
performance and to reduce wear. Inspect and properly
tighten all parts each time the elliptical is used.
Replace any worn parts immediately.
To clean the elliptical, use a damp cloth and a small
amount of mild soap. IMPORTANT: To avoid damage
to the console, keep liquids away from the console
and keep the console out of direct sunlight.
CONSOLE TROUBLESHOOTING
If the console does not turn on, make sure that the
power adapter is fully plugged in.
If the console does not display your heart rate when
you hold the handgrip heart rate monitor, or if the dis-
played heart rate appears to be too high or too low, see
step 5 on page 20.
If the console does not display your heart rate
when you use the chest heart rate monitor, see
TROUBLESHOOTING on page 13.
If a replacement power adapter is needed, call the
telephone number on the cover of this manual.
IMPORTANT: To avoid damaging the console, use
only a manufacturer-supplied regulated power
adapter.
TABLET HOLDER TROUBLESHOOTING
If the tablet holder does
not stay in place, rotate
the tablet holder backward
and tighten the screw (A)
until the tablet holder stays
in place when it is rotated
to the desired position.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted. Before you adjust the
reed switch, unplug the power adapter.
Using a standard screwdriver, carefully pry off the Left
Shield Disc (103).
Next, locate the Reed Switch (86). Move the ped-
als until one of the Magnets (88) on the Pulley (53)
is aligned with the Reed Switch. Then, loosen the
M5 x 16mm Flat Head Screw (99), slide the Reed
Switch slightly toward or away from the Magnet, and
retighten the Flat Head Screw.
Plug in the power adapter and move the pedals for-
ward and backward slightly so that the Magnet (88)
passes the Reed Switch (86) repeatedly. Repeat these
actions until the console displays correct feedback.
When the Reed Switch (86) is correctly adjusted,
unplug the power adapter. Then, reattach the Left
Shield Disc (103) and plug in the power adapter.
A
103
53
88
99
86