Inspect and tighten all parts of the exercise bike
regularly. Replace any worn parts immediately.
To clean the exercise bike, use a damp cloth and a
small amount of mild soap.
IMPORTANT: To avoid
damage to the console, keep liquids away from
the console and keep the console out of direct
sunlight.
CONSOLE TROUBLESHOOTING
If the console does not display your heart rate when
you use the handgrip heart rate monitor, see step 5 on
page 18.
If lines appear in the console display, see HOW TO
CHANGE CONSOLE SETTINGS on page 24 and
adjust the contrast level of the display.
If a replacement power adapter is needed, call the
telephone number on the cover of this manual.
IMPORTANT: To avoid damaging the console, use
only a manufacturer-supplied regulated power
adapter.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted.
To adjust the reed
switch, first
unplug the
power adapter.
Next,
use a flat screwdriver
and release the tabs
on the Accessory Tray
(5), and then lift the
Accessory Tray away
from the frame.
Next, locate the Reed Switch (78). Loosen, but do not
remove, the M4 x 12mm Washer Head Screw (65).
Next, rotate the Pulley (75) until a Magnet (67) is
aligned with the Reed Switch (78). Slide the Reed
Switch slightly toward or away from the Magnet. Then,
retighten the M4 x 12mm Washer Head Screw (65).
Plug in the power adapter and rotate the Pulley (75)
for a moment. Repeat these actions until the console
displays correct feedback.
When the reed switch is correctly adjusted, reattach
the accessory tray and plug in the power adapter.