inches (mm)
A1
A2
A3
A4
b1
b2
b3
ROSA REVERSE UL-C
40 in (1016 mm)
10 in (254 mm)
10 in (254 mm)
15 in (381 mm)
16 in (406 mm)
8 in (203 mm)
2 in (50.8 mm)
ROSA SINISTRA
REVERSE UL-C
40 in (1016 mm)
10 in (254 mm)
10 in (254 mm)
15 in (381 mm)
16 in (406 mm)
8 in (203 mm)
2 in (50.8 mm)
ROSA UL-C
40 in (1016 mm)
10 in (254 mm)
10 in (254 mm)
15 in (381 mm)
16 in (406 mm)
8 in (203 mm)
2 in (50.8 mm)
007095315-001
Interior Vertical Vents
Through the wall installation
A1
A2
A4
B3
A3
B2
B2
B1
A1
A2
A4
B3
A3
B2
B2
B1
Interior Vertical Vents
Through the wall installation
A1
A2
A4
B3
A3
B2
B2
B1
A1
A2
A4
B3
A3
B2
B2
B1
3.1.1 STRAIGHT INSTALLATION
3.1.2 FLOOR PROTECTION INSTALLATION REQUIREmENTS
Picture 1
Picture 2
Floor Protection
Floor Protection
c) If the product is installed on a flammable floor, a floor protection must be installed.
The floors made of flammable material
,
such as moquette, parquet or cork etc.,
must be covered
by a floor protector. SUCH FLOOR PROTECTOR SHALL BE A LISTED UL
1618 MATERIAL.
The floor protector shall be placed under the appliance and it must extend at least
16-in (419 mm)
beyond the front and at least
8-in (203 mm)
beyond each side of the fuel loading and ash removal opening (see
Picture 2
- distance
b
).
17