PARTS DESCRIPTION 

 

DESCRIPTION 

PIÈCES 

Floor protector (Non combustible) 

21 

6’’ single or double pipe 

22 

Certified Chimney 2100 

23 

Hat 

24 

Attic Radiation shield 

25 

Decorative Ceiling Support 

26 

Adaptor 

27 

Roof Plaster Filling 

28 

Fan 

29 

 

REFER TO PAGE 14-15 

 

FLOOR PROTECTION 

If you have a concrete floor, you can install your stove directly on it. For the installation and conform use according to the 
manufacturer’s instruction and the local building codes, the unit must be installed on a 3/8’’ (9.5 mm) thick concrete plate 
(Duroc) or an equivalent, extending 18’’ (457 mm) in front and 8’’ (203 mm) in the back and on the sides. See figure below.

 

 

 

 

Содержание natural warmth

Страница 1: ... on the manufacturer s website Soca Industries INC 11740 Philippe Panneton Montreal Quebec H1E 4G4 Tel 514 494 4522 Tel 1 888 494 4522 Fax 514 494 4521 www foyersnordica com info industriessoca com MEETS TEST STANDARDS ULC 5627 UL 1482 CERTIFIED BY THE U S ENVIRONMENTAL PROTECTION AGENCY EPA ...

Страница 2: ...NANCE OF PLATED SURFACES 8 CHIMNEY MAINTENANCE 8 ASHES 8 MOBILE HOME INSTALLATION 9 TYPE OF CHIMNEY 9 CHIMNEY 9 CHIMNEY MINIMUM HEIGHT 10 FRESH AIR INTAKE BACK DRAFTING 10 CHIMNEY FIRE 11 SMOKE DETECTOR 11 AIR ENTRANCE 11 OUTSIDE AIR INTAKE INSTALLATION 11 STANDARD INSTALLATION 12 PARTS DESCRIPTION 13 FLOOR PROTECTION 13 STOVE AND CHIMNEY INSTALLATION DIAGRAM 14 CHIMNEY INSTALLATION DIAGRAM 15 25 ...

Страница 3: ...king note of all lawful requirements in force In many cases a construction permit is necessary The equipment s installation will be made according to rules of authority having jurisdiction on Warnock Hersey Code of installation for wood heating equipment CAN CSA B365 The choice of location of the stove is very important Preferably choose the most central part of the house so that heat is distribut...

Страница 4: ...e liquid to start or activate a fire Keep those products away from the heat source D When the stove is used for the first time make small fires in order to allow the firebrick to solidify themselves E During these first fires the stove s paint can release odour and smoke Open a window to decrease these disturbances It has also been proven necessary to open a window in the case of an airtight house...

Страница 5: ... burn seasoned wood to obtain a better quantity of heat per cordwood Burn reasonable loads do not overload the stove and ensure that the logs are placed in order not to fall against the glass or to burn too close to the glass Use seasoned wood only Note that 6 12 months are needed for drying to have seasoned wood of 15 to 20 of moisture Important Do not store wood near stove MANUFACTURED LOGS The ...

Страница 6: ... they are completely closed GLASS Never slam the door or strike the glass When you close the door ensure yourself that the logs are placed in order not to fall against the glass or to burn too close to the glass Never clean the glass with abrasive cleaners The scratches could be transformed into cracks and glass could break Never try to clean the hot glass when the stove is on You can find the cle...

Страница 7: ...r s junction 3 Glass support to prevent them from coming down 4 Center glass 5 Side glasses 6 Glass Outline 7 Door s inside frame 8 Washers 9 Nuts 10 3 4 gasket REMPLACEMENT OF FIREBRICKS Do not use the stove when a brick is missing or when she is broken You can purchase the firebricks replacement at your retailer or from the Soca Industries INC ...

Страница 8: ...y use a soft damp during maintenance CHIMNEY MAINTENANCE It is important to inspect the chimney or clean it periodically It is necessary to have the chimney cleaned after an accumulation of 3 mm of creosote After two months of usage it would be preferable to have the chimney cleaned as well as to dismantle the pipe of the stove and remove the soot and creosote Before beginning each heating season ...

Страница 9: ...on please refer to the manufacturer s manual of the selected chimney CHIMNEY The stove should not be connected to any other distribution system such as incinerator heating system or ventilation system This unit requires a masonry chimney or a certified prefabricated chimney 2100 and its components must conform to the Canadian standards and having appropriate dimensions If the chimney is a masonry ...

Страница 10: ...fan bathroom ventilator central vacuum cleaner or drier intakes the air towards outside may create a negative pressure in the house Close them or open a window near the stove to regulate this problem 6 Wet wood releases more smoke while burning than seasoned wood The wetter the wood is the less heat it releases the more it produces creosote If the wood burnt is very wet have the chimney inspected ...

Страница 11: ...because it will go off when opening the door for loading AIR ENTRANCE It is prohibited to modify the air intake in any way OUTSIDE AIR INTAKE INSTALLATION The external air intake kit must be installed according to the following instructions 1 The maximum length of the duct must be of 20 feet The length of the duct should be as short as possible 2 The air register should not be installed more than ...

Страница 12: ... be reduced by approval of the authorities COMBUSTIBLE RELEASES Single sided pipe See illustrated figure Units Pipe A Back wall 14 21 5 B Lateral wall 16 28 C Corner on the wall 10 19 Ceiling 7 N A Front wall 48 N A Double sided pipe See illustrated figure Units Pipe A Back wall 8 14 B Lateral wall 16 28 C Corner on the wall 5 14 Ceiling 7 N A Front wall 48 N A Operation Conditions Door Closed Fan...

Страница 13: ...er Filling 28 Fan 29 REFER TO PAGE 14 15 FLOOR PROTECTION If you have a concrete floor you can install your stove directly on it For the installation and conform use according to the manufacturer s instruction and the local building codes the unit must be installed on a 3 8 9 5 mm thick concrete plate Duroc or an equivalent extending 18 457 mm in front and 8 203 mm in the back and on the sides See...

Страница 14: ...14 STOVE AND CHIMNEY INSTALLATION DIAGRAM REFER TO DESCRIPTION ON PAGE 13 ...

Страница 15: ...15 CHIMNEY INSTALLATION DIAGRAM REFER TO DESCRIPTION ON PAGE 13 ...

Страница 16: ...by this warranty The Soca Industries INC assumes no liability in the event of a back drafting problem resulting from a negative pressure of the property caused by a heating ventilation air exchanger system or any structural component that can cause this problem WARRANTY CONDITIONS 1 Garantee is valid only for the original purchaser The warranty is not transferable 2 Each complaint must be accompan...

Страница 17: ...______________________________________________________________________ City of the store ______________________________ Province ____________________________________ OTHER INFORMATION Application Renovation Improvement of the heater Other ________________________________ Area of installation Living room Basement Other ________________________________ Principal use of heating Electricity Gas Wood O...