PRELIMINARY: 24-Sep-2021
Page 9
002536MAN-00
Installation Basics
Sample Bill of Materials -
ATWC Series
FROM MARITIME GEOTHERMAL
• ATWC SERIES HEAT PUMP W/ACEC OUTDOOR UNIT
• SHIELDED DOUBLE TWISTED PAIR WIRE
• BUFFER TANK W/ELEMENTS 12/15/20 kW
OPTIONAL FROM MARITIME GEOTHERMAL
• ANTI-VIBRATION PAD
• COMPRESSOR SOUND JACKETS (2)
• COMPRESSOR SECURE STARTS (2)
• AHW-65 AIR HANDLER(S)
ELECTRICAL
• HEAT PUMP SERVICE WIRE: 3-3, 4-3, 6-3, OR 8-3
• BUFFER TANK ELEMENT SERVICE WIRE
• 14-2 OUTDOOR RATED WIRE W/ DISCONNECT
SWITCH FOR OUTDOOR UNIT
• HEAT PUMP BREAKER: 40 TO 100A
• BUFFER TANK ELEMENT BREAKER
• ELEMENT CONTACTOR & ELEC. BOX
(IF NOT USING TANK W/ DRY CONTACTS)
• THERMOSTAT WIRE 18-4
• THERMOSTAT WIRE 18-2
• FORK TERMINALS FOR TSTAT WIRE (6)
REFRIGERATION
• 1/2” & 7/8” (OR 3/8” & 3/4”) ACR TUBING
• PIPE INSULATION
• EXTRA R410A & R134a REFR. FOR LINESETS >20 FT
HYDRONICS
• CIRCULATOR: HEAT PUMP TO TANK
• PIPE & FITTINGS: HEAT PUMP TO TANK
• ZONES CIRCULATOR(S)
• ZONE TRANSFORMER & CIRC CONTACTOR
• ZONE VALVES (IF NOT INDIVIDUAL PUMPS)
• ZONE PIPING
• OTHER AIR HANDLERS, DUCTING
• ZONE THERMOSTATS
• RELAYS OR ZONE CONTROLLER
• ZONE SUPPLY & RETURN HEADERS:
1” COPPER PIPE & FITTINGS
• PIPE & FITTINGS TO ZONES
• EXPANSION TANK
• 2” STYROFOAM INSUL. (IF PAD NOT PURCHASED)
Unpacking the Unit
When the 2-piece heat pump reaches its destination it
should be unpacked to determine if any damage has occurred
during shipment. Any visible damage should be noted on the
carrier's freight bill and a suitable claim filed at once.
Indoor Unit Placement
The the indoor unit should be placed near the outdoor unit
to keep the two refrigerant line sets as short as possible. The
line sets have a maximum length of 70 ft (21 m) but should be
as short as possible for maximum efficiency.
The front and two side access panels should remain clear
of obstruction for a distance of
two feet
to facilitate servicing
and general maintenance. No access is required on the back
side.
An anti-vibration pad, available as an accessory, or a
piece of 2” styrofoam should be placed under the unit. This will
deaden vibrations and protect the cabinet from rusting.
* See Piping chapter for an annotated copy of this diagram
Содержание ATWC Series
Страница 15: ...PRELIMINARY 24 Sep 2021 Page 15 002536MAN 00...
Страница 16: ...PRELIMINARY 24 Sep 2021 Page 16 002536MAN 00...
Страница 17: ...PRELIMINARY 24 Sep 2021 Page 17 002536MAN 00...
Страница 18: ...PRELIMINARY 24 Sep 2021 Page 18 002536MAN 00...
Страница 20: ...PRELIMINARY 24 Sep 2021 Page 20 002536MAN 00...
Страница 21: ...PRELIMINARY 24 Sep 2021 Page 21 002536MAN 00...
Страница 22: ...PRELIMINARY 24 Sep 2021 Page 22 002536MAN 00...
Страница 23: ...PRELIMINARY 24 Sep 2021 Page 23 002536MAN 00...
Страница 24: ...PRELIMINARY 24 Sep 2021 Page 24 002536MAN 00...
Страница 25: ...PRELIMINARY 24 Sep 2021 Page 25 002536MAN 00...
Страница 26: ...PRELIMINARY 24 Sep 2021 Page 26 002536MAN 00...
Страница 27: ...PRELIMINARY 24 Sep 2021 Page 27 002536MAN 00...
Страница 28: ...PRELIMINARY 24 Sep 2021 Page 28 002536MAN 00...
Страница 31: ...PRELIMINARY 24 Sep 2021 Page 31 002536MAN 00...
Страница 81: ...PRELIMINARY 24 Sep 2021 Page 81 002536MAN 00...
Страница 82: ...PRELIMINARY 24 Sep 2021 Page 82 002536MAN 00...
Страница 83: ...PRELIMINARY 24 Sep 2021 Page 83 002536MAN 00...
Страница 84: ...PRELIMINARY 24 Sep 2021 Page 84 002536MAN 00...
Страница 85: ...PRELIMINARY 24 Sep 2021 Page 85 002536MAN 00...
Страница 86: ...PRELIMINARY 24 Sep 2021 Page 86 002536MAN 00...
Страница 87: ...PRELIMINARY 24 Sep 2021 Page 87 002536MAN 00...
Страница 88: ...PRELIMINARY 24 Sep 2021 Page 88 002536MAN 00...
Страница 89: ...PRELIMINARY 24 Sep 2021 Page 89 002536MAN 00...
Страница 90: ...PRELIMINARY 24 Sep 2021 Page 90 002536MAN 00...
Страница 91: ...PRELIMINARY 24 Sep 2021 Page 91 002536MAN 00...
Страница 92: ...PRELIMINARY 24 Sep 2021 Page 92 002536MAN 00 Dimensions ATWC 45 55...
Страница 93: ...PRELIMINARY 24 Sep 2021 Page 93 002536MAN 00 Dimensions ATWC 45 55...
Страница 94: ...PRELIMINARY 24 Sep 2021 Page 94 002536MAN 00 Dimensions ATWC 65...
Страница 95: ...PRELIMINARY 24 Sep 2021 Page 95 002536MAN 00 Dimensions ATWC 65...
Страница 96: ...PRELIMINARY 24 Sep 2021 Page 96 002536MAN 00 Dimensions ATWC 75 80 100...
Страница 97: ...PRELIMINARY 24 Sep 2021 Page 97 002536MAN 00 Dimensions ATWC 75 80 100...