7. CONNECTION TO THE MAINS
1
. Ensure that mains voltage and frequency are the same as those stated on the rating plate (A) attached
to the appliance. . Ensure that the supply socket:
2
a)
b)
is properly earthed;
fulfils the requirements of the
rated current as set out on the rating plate;
complies with the IEC regulations:- thermal-magnetic
c)
switch with In = rated value as stated on the rating plate; - differential with Id sensitivity = 30 mA.
.
3
Ensure that there is no danger of explosion (AD) in the room. . Make sure the environment is suitable for
4
the power supply cable provided. The cable of the appliance is H05 VVF, designed for internal use.
5
N.B.:
. Insert the plug in the socket (do not use three-way adapters and reduction adapters).
if the
equipment has been transported or stored overturned, let is rest in its correct position for at least 3 hours
before hooking it up to the mains (see fig. 5).
8. CONTROLS
The appliance features controls situated in a protected panel on the front side.
to
1. Cover lifting switch:
open and close the cover - Position II to lift - Position O to stop - Position I to lower.
to
2. Light switch:
switch on the internal lights.
to switch on the refrigeration unit.
3. Refrigeration switch:
4. Thermometer
Thermostat:
: to read the temperature in the counter.
to adjust the temperature setting.
a) Press key
to display the temperature set-point, which can be changed by pressing key
5
“
SET or P
”
6
“
UP
”
7
“
DOWN
”
or
(see fig. 6).
9. CHECKING CORRECT OPERATION
Make sure that: 1.
2.
the plug is connected;
the refrigeration unit switch is on (green light lit up);
3
4
. thermometer shows the desired temperature for the goods to be stored; . appliance is not exposed to
direct sunlight or to powerful lamps;
ambient temperature does not 30°C with 55% R.H.
5.
(climatic class 4); . there are no direct air draughts in the appliance, coming from the appliance itself,
6
owing to the presence of doors, windows, fans or conditioner outlets.
10. INTERNAL CLEANING
1.
2.
Switch off the appliance.
Check the evaporator fins for frost or ice. Should the layer of frost be too
thick, and ice drips are noted that could impair passage of air, complete defrosting should be undertaken.
Remove goods and store them in another suitable refrigerator running at the same temperature.
3.
4
Remove the plug in the bottom section of the machine. . Clean the walls and accessories with a
sponge dipped in water and sodium bicarbonate. Take care not to touch the evaporator fins, which
feature sharp edges. . Dry all parts with care and refit all components. Refit the plug before turning on
5
the appliance.
11. REPLACEMENT OF THE LAMP (VT-VTL)
1
2
3.
. Open the cover. . Switch off the appliance.
Remove the screws securing one of the lamp sockets in
place. . Remove the lamp socket, whilst holding the fluorescent tube and its protective cover. . Pull the
4
5
protective cover out of the other lamp socket. . Replace the fluorescent tube. . Refit all components by
6
7
following the above instructions in reverse order (see fig. 7).