DIP switches
The 4 existing dip switches are used to set the operating mode
and the adjustable time range of a potentiometer. The following
table provides an overview for the setting of the operating mode
as well as the corresponding assignment of individual functions,
potentiometers and time ranges.
Switch position:
1 = ON
0 = OFF
Dip switch
1
2
Operating mode
(Binary code or switch position)
0
0
P3
Run-down moment
P4
Run-down time
P1
Start-up moment
P2
Start-up time
0
1
P3
Initial breakaway
moment
P4
Initial breakaway time
P1
Start-up/Run-down
moment
P2
Start-up/Run-down time
1
0
P3
Initial breakaway
moment
P4
Initial breakaway time
P1
Start-up moment
P2
Start-up time/
Engagement time of
brake
1
1
P3
Initial breakaway
moment
P4
Initial breakaway time
P1
Start-up moment
P2
Start-up time
Dip switch 3
Æ
Time range P2:
1 [ON] = 2 – 60 s
0 [OFF] = 0.5 – 10 s
Dip switch 4
Æ
Time range P4:
1 [ON] = 2 - 60s
(At “Increased initial breakaway moment”: 0.2 – 6 s)
0 [OFF] = 0,5 - 10s
(At “Increased initial breakaway moment”: 0,05 – 1 s)