![Norcool CU-350 ECO Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/norcool/cu-350-eco/cu-350-eco_operating-and-installation-instructions-manual_1701171016.webp)
16
6. Using the Appliance
6.1 Replacing the LED bars for CU-350 ECO/CU-450 ECO/CU-900 ECO
The LED bars must be replaced by authorized technician.
6.2 Controller icons and temperature settings
The unit is equipped with an electronic controller located on the cover of the cold side
Indicates compressor is activated.
Indicates fan is activated.
Indicates defrosting is activated.
Indicates parameter programming.
Indicates buzzer alarm occurred.
The controller has a range of 2 °C – 18 °C, with default setting of 5 °C. In order to
adjust the set point please follow the below steps:
• Press and hold ‘SET’ for two seconds, the display will flash the current set
point value.
• Press ‘UP’ or ‘DOWN’ arrow button to adjust the temperature.
• Press ‘SET’ again or do nothing for 30 seconds and the system will automati-
cally save the setting and end setting mode
6.3 Switching on / off the light
• Press ‘Lig’ to turn on/off the light.
6.4 Manual defrost
• Press and hold ‘def/down’ button for 8 seconds to start manual defrost. The
defrost will stop automatically when the deicing temperature is reached.
6.5 Alarm function
If the temperature of the compressor exceeds a specific value the controller will
generate an audible alarm. If the alarm sounds and the display show the code
“ACH” you need to clean the condenser filter and the condenser as described in
the “Cleaning & Maintenance” section and reset the alarm by pressing the “Mute’’
controller button. If the problem persists, please order service call.
If the compressor’s temperature exceeds the compressor’s operating temperature
limits, the controller will generate an audible alarm and shut down the cooling sys-
tem, as high temperatures can reduce the cooler’s service life considerably. In this
case you need to clean both the filter and the condenser as described in the “Clean-
ing & Maintenance” section, and reset the alarm and the cooling system by pressing
the “Mute’’ controller button. If the problem persists, please order service call.
Set
Lig
def
Содержание CU-350 ECO
Страница 1: ...CU 350 ECO CU 450 ECO CU 900 ECO English OPERATING INSTALLATION INSTRUCTIONS ...
Страница 2: ...2 Please visit www norcool no for operating installation instructions in other languages ...
Страница 3: ...3 Shape ...
Страница 4: ......
Страница 23: ......