6. Pull the burner box away from the refrigerator until the burner, ignition electrode, and

thermocouple are visible.

7. Remove gasket material from the top flange of the burner box.

8. Pull the thermocouple away from the burner box until two clicks are heard.

Do not pull the thermocouple completely out of the burner box.

9. Push the thermocouple into the burner box. The thermocouple tip must be positioned

over the first slot of the burner as illustrated in Figure 6 on page 6.

10. Install the new gasket material around flange of burner box.

Caution:  Do not install a damaged gasket. Use care when handling the replacement

gasket material. If torn, a new gasket (Part # 617977) must be ordered.
Call 1-800-543-1219 to place order.

11. Re-attach the burner box to the cooling unit. Insure the gasket remains around the

flange of the burner box.

Burner Shield Installation (Rialta and Eurovan Camper) - Reference Figure 7

 12. Remove the screw located on the right front face of the burner box and save it for later

installation.

13. Slide the heat shield between the refrigerator’s cabinet and burner box. 

It may be

necessary to lift the burner box up to position the burner shield in place. Secure
the heat shield to the burner box with the screw removed in Step 12.

14. Align the side of the heat shield with bottom of the refrigerator’s support bracket. Secure

the heat shield with the two self-tapping screws provided with the kit.

Heat Shield

(Side View)

Heat Shield

Remove this screw and

save for re-installation.

Burner Box

Figure 7 - Heat Shield Installation

7

Содержание 3163G

Страница 1: ...in the gas mode should operate their refrigerator on AC or DC until the upgrade kit is installed All product upgrades are to be completed by an authorized dealer or service center The refrigerator mod...

Страница 2: ......

Страница 3: ...Figure 1 Before Upgrade Figure 2 After Upgrade 1...

Страница 4: ...ex Head Driver 1 Volt Ohmmeter 1 7 16 Open End Wrench 1 1 2 Open End Wrench 1 5 8 Open End Wrench 1 Manometer 1 3 8 Power Drill 1 3 32 Drill Bit 1 1 16 Drill Bit Specifications Installation of the upg...

Страница 5: ...ove the monitor panel located directly above the refrigerator by removing 6 retaining screws CAUTION It is not necessary to disconnect wiring from the monitor panel Pull panel forward and away from th...

Страница 6: ...ches when connecting or disconnecting gas fittings 12 Remove the three 3 screws securing the vent cover to the vehicle s exterior surface See Figure 3 13 Remove the two 2 screws securing the inner dis...

Страница 7: ...the refrigerator Remove the access panel at the rear of the cabinet This will allow access to the refrigerator s vent air intake and exhaust piping Note Observe the routing of the existing flexible p...

Страница 8: ...st removed 4 Install the orifice received Red Dot with the upgrade kit by reversing the above procedures CAUTION Do not over tighten the orifice or the burner tube connections Over tightening these co...

Страница 9: ...st be ordered Call 1 800 543 1219 to place order 11 Re attach the burner box to the cooling unit Insure the gasket remains around the flange of the burner box Burner Shield Installation Rialta and Eur...

Страница 10: ...ng a phillips screwdriver remove the screw securing the single 45 terminal Remove and discard the terminal Attach the supplied double 45 spade terminal with the screw just removed 3 Re attach the whit...

Страница 11: ...Connect the 3 pigtail to the 1 amp fuse holder Connect the remaining end to the 12 volt DC terminal of the terminal block Modify Wiring of the Refrigerator Electrical Circuit Reference Figures 1 2 11...

Страница 12: ...e two fan wires are not constricted in any way 4 Insert the two 1 1 4 screws provided with this kit through the clearance holes of the fan assembly A and into the pilot holes in the mounting support b...

Страница 13: ...drilled in Step 2 5 Insert the two 6 x 3 8 screws provided with the kit through the clearance holes of the thermostat and into the pilot holes in the cooling units condenser fins 6 Tighten screws to...

Страница 14: ...the Ohmmeter in the Ohms mode Connect the ohmmeter leads to the AC input terminals on the terminal block 5 With the thermostat in the start position the ohmmeter should measure an open circuit in all...

Страница 15: ...follows Exhaust Pipe This pipe is insulated and connects to the flue tube of the cooling unit Route and connect to the bottom opening of the vent terminal housing Intake Pipe This pipe is not insulate...

Отзывы: