Norcold 3163G Скачать руководство пользователя страница 1

IMPORTANT PRODUCT INFORMATION

Norcold refrigerator models 3163T and 3163G installed in the Rialta and Eurovan Camper may

experience a cooling deficiency while operating in the gas mode. The cooling deficiency occurs

when the vehicle’s interior ambient temperatures are 90

°

F or higher. Performance while

operating in the AC or DC modes is not affected.

To rectify this deficiency, Norcold offers a product upgrade kit. This kit is available through the

Winnebago service network. Customers who experience cooling deficiencies while operating

in the gas mode should operate their refrigerator on AC or DC until the upgrade kit is installed.

All product upgrades are to be completed by an authorized dealer or service center.

The refrigerator models 3163T and 3163G installed in the Rialta and Eurovan Camper are the

only Norcold refrigerator models affected with this cooling deficiency. The following is the list of

product serial numbers which are affected.

3163T

3163G

Serial Number Range

Serial Number Range

001001CLTPC4   -   001850CLTPH4

001001CMGYC4   -   002150CMGYH4

Accompanying this notice are complete instructions for installing the product upgrade kit, tool

requirements, and time allotted for installation. Removal of the refrigerator from its enclosure is

required.

Part No.: 618081C

Содержание 3163G

Страница 1: ...in the gas mode should operate their refrigerator on AC or DC until the upgrade kit is installed All product upgrades are to be completed by an authorized dealer or service center The refrigerator mod...

Страница 2: ......

Страница 3: ...Figure 1 Before Upgrade Figure 2 After Upgrade 1...

Страница 4: ...ex Head Driver 1 Volt Ohmmeter 1 7 16 Open End Wrench 1 1 2 Open End Wrench 1 5 8 Open End Wrench 1 Manometer 1 3 8 Power Drill 1 3 32 Drill Bit 1 1 16 Drill Bit Specifications Installation of the upg...

Страница 5: ...ove the monitor panel located directly above the refrigerator by removing 6 retaining screws CAUTION It is not necessary to disconnect wiring from the monitor panel Pull panel forward and away from th...

Страница 6: ...ches when connecting or disconnecting gas fittings 12 Remove the three 3 screws securing the vent cover to the vehicle s exterior surface See Figure 3 13 Remove the two 2 screws securing the inner dis...

Страница 7: ...the refrigerator Remove the access panel at the rear of the cabinet This will allow access to the refrigerator s vent air intake and exhaust piping Note Observe the routing of the existing flexible p...

Страница 8: ...st removed 4 Install the orifice received Red Dot with the upgrade kit by reversing the above procedures CAUTION Do not over tighten the orifice or the burner tube connections Over tightening these co...

Страница 9: ...st be ordered Call 1 800 543 1219 to place order 11 Re attach the burner box to the cooling unit Insure the gasket remains around the flange of the burner box Burner Shield Installation Rialta and Eur...

Страница 10: ...ng a phillips screwdriver remove the screw securing the single 45 terminal Remove and discard the terminal Attach the supplied double 45 spade terminal with the screw just removed 3 Re attach the whit...

Страница 11: ...Connect the 3 pigtail to the 1 amp fuse holder Connect the remaining end to the 12 volt DC terminal of the terminal block Modify Wiring of the Refrigerator Electrical Circuit Reference Figures 1 2 11...

Страница 12: ...e two fan wires are not constricted in any way 4 Insert the two 1 1 4 screws provided with this kit through the clearance holes of the fan assembly A and into the pilot holes in the mounting support b...

Страница 13: ...drilled in Step 2 5 Insert the two 6 x 3 8 screws provided with the kit through the clearance holes of the thermostat and into the pilot holes in the cooling units condenser fins 6 Tighten screws to...

Страница 14: ...the Ohmmeter in the Ohms mode Connect the ohmmeter leads to the AC input terminals on the terminal block 5 With the thermostat in the start position the ohmmeter should measure an open circuit in all...

Страница 15: ...follows Exhaust Pipe This pipe is insulated and connects to the flue tube of the cooling unit Route and connect to the bottom opening of the vent terminal housing Intake Pipe This pipe is not insulate...