background image

 

 

 

Maintain a balanced body position and secure footing. 

 

Release the trigger in the case of an interruption of the energy supply. 

 

Use only lubricants recommended by the manufacturer. 

 

Do not use in confined spaces and beware of crushing hands between tool and workpiece. 

Repetitive Motions Hazards:

 

 

 

When using a power tool for threaded fasteners, the operator can experience discomfort in the hands, 

arms, shoulders, neck, or other parts of the body. 

 

While using an assembly power tool for threaded fasteners, the operator should adopt a comfortable 

posture whilst maintaining secure footing and avoiding awkward or off-balanced postures. The operator 

should change posture during extended tasks, which can help avoid discomfort and fatigue. 

 

If the operator experiences symptoms such as persistent or recurring discomfort, pain, throbbing, 

aching, tingling, numbness, burning sensations or stiffness, these warning signs should not be ignored. 

The operator should tell the employer and consult a qualified health professional. 

Accessory Hazards:

 

 

 

Disconnect the assembly power tool for threaded fasteners from the energy supply before changing the 

tool or accessory. 

 

Use only sizes and types of accessories and consumables that are recommended by the assembly 

power tool for threaded fasteners manufacturer; do not use other types or sizes of accessories and 

consumables. 

Workplace Hazards:

 

 

 

Slips, trips and falls are major causes of workplace injury. Be aware of slippery surfaces caused by the 

use of the tool and also of trip hazards caused by the air line or hydraulic hose. 

 

Proceed with care in unfamiliar surroundings. Hidden hazards, such as electricity or other utility lines, 

can exist. 

 

The assembly power tool for threaded fasteners is not intended for use in potentially explosive 

atmospheres and is not insulated against coming into contact with electrical power. 

 

Make sure there are no electrical cables, gas pipes, etc., that can cause a hazard if damaged by use of 

the tool. 

Dust and Fume Hazards:

 

 

 

Dust and fumes generated when using assembly power tools for threaded fasteners can cause ill health 

(for example, cancer, birth defects, asthma and/or dermatitis); risk assessment and implementation of 

appropriate controls for these hazards are essential. 

 

Risk assessment should include dust created by the use of the tool and the potential for disturbing 

existing dust. 

 

Direct the exhaust to minimize disturbance of dust in a dust-filled environment. 

 

Where dust or fumes are created, the priority shall be to control them at the point of emission. 

 

All integral features or accessories for the collection, extraction or suppression of airborne dust or fumes 

should be correctly used and maintained in accordance with the manufacturer's instructions. 

 

Use respiratory protection in accordance with employer's instructions and as required by occupational 

health and safety regulations. 

Содержание 16011.X

Страница 1: ...TOOLS INC 36400 Biltmore Place Willoughby Ohio 44094 USA Tel 1 866 667 2279 Email inquiry norbar us NORBAR TORQUE TOOLS PTE LTD 194 Pandan Loop 07 20 Pantech Business Hub SINGAPORE 128383 Tel 65 6841...

Страница 2: ...arkings on Tool 6 Introduction 7 Part Included 7 Accessories 7 Features and Functions 8 Set up Instructions 9 Torque Reaction 9 Examples of Tool Control Systems 11 Input Ports 12 Exhaust Port 12 Setti...

Страница 3: ...7 XAUT 1 3 400 N m PT 7 16066 X 16066 XMTS 16066 XAUT 1 6 000 N m PT 9 16072 X 16072 XMTS 16072 XAUT 1 9 500 N m PT 11 16046 X 16046 XMTS 2 20 000 N m PT 12 18086 X 18086 XMTS 2 34 000 N m PT 13 16052...

Страница 4: ...iles Always wear impact resistant eye protection during the operation of the assembly power tool for threaded fasteners The grade of protection required should be assessed for each use Ensure that the...

Страница 5: ...sories and consumables Workplace Hazards Slips trips and falls are major causes of workplace injury Be aware of slippery surfaces caused by the use of the tool and also of trip hazards caused by the a...

Страница 6: ...sembly power tool for threaded fasteners tell your employer and consult a physician Operate and maintain the assembly power tool for threaded fasteners as recommended in the operator s manual to preve...

Страница 7: ...sult of each use This Operator s Manual contains sufficient information for the end user to be able to perform an initial risk assessment Unexpected direction of drive square movement can cause a haza...

Страница 8: ...ommended compressor rating 6 9 bar 100 psi 19 l s 40 CFM Lubro Control Unit or similar Filter Regulator and Lubricator Unit Bore 12 mm Impact or high quality sockets Parts Included Model Part Number R...

Страница 9: ...n is at 5 times normal operating speed before it automatically changes gear to apply the final torque Manual Two Speed MTS The manual two speed gearbox option allows manual selection of slow or fast s...

Страница 10: ...Size Fixing Bolt Torque PT 1 PT 2 16420 2BA 9 N m PT 5 PT 6 16544 BSF 19 N m PT 7 16263 M10 83 N m PT 9 16387 BSF 75 N m PT 11 16322 M10 83 N m PT 12 18994 M12 150 N m PT 13 16330 M16 310 N m PT 14 1...

Страница 11: ...tensions is available for applications where access is restricted These are designed to support the final drive correctly When the PneuTorque is in operation the reaction arm rotates in the opposite d...

Страница 12: ...se from the supply to the control system must not be longer than 5 metres or the tools performance will be impaired If the supply hose must be longer than 5 metres then bore must be used Examples of t...

Страница 13: ...kwise REV BSP connectors as shown in Figure 9 Exhaust Port The exhaust port located on the side of the tool is common to both inlet ports TIP As with any pneumatic tool a fine oil mist is present in t...

Страница 14: ...adjust the air pressure regulator until the correct pressure is shown on the air pressure gauge IMPORTANT THE TOOL MUST BE FREE RUNNING WHILE ADJUSTING THE AIR PRESSURE TO GIVE THE CORRECT SETTING WH...

Страница 15: ...the tool onto the fastener Locate reaction arm adjacent to the reaction point 4 Complete the following instructions for SINGLE SPEED AUTOMATIC TWO SPEED or MANUAL TWO SPEED tools Single Speed Part Nu...

Страница 16: ...ool and remove from fastener TIP If the tool will not release from the bolt run tool in the opposite direction for a fraction of a second NOTE If the air pressure is released before the tool stalls fu...

Страница 17: ...e Every week check that the bolts fastening the reaction plate are tightened to the torque stamped onto the reaction plate Air Lubrication Add Fuchs Silkair VG22 or Shell Tellus S2 VX15 or equivalent...

Страница 18: ...screw 25353 60 Circlip 26432 16 18 PT 13 2 16310 M6 screw 25353 60 Circlip 26432 16 18 PT 14 3 16309 M6 screw 25353 60 16 18 PT 15 Application specific PT 16 Application specific PT 17 Application sp...

Страница 19: ...min 45 rev min 508 019 1 93 137 1 PT 5 880 N m 650 lbf ft 3400 N m 2500 lbf ft 5 rev min 25 rev min 885 185 1 162 284 1 PT 6 880 N m 650 lbf ft 3400 N m 2500 lbf ft 5 rev min 25 rev min 885 185 1 162...

Страница 20: ...17 9 23 2 6 3 PT 9 184 376 462 445 169 351 24 4 27 9 8 3 PT 11 212 470 556 500 38 6 42 1 13 3 PT 12 240 593 679 Blank plate 49 8 53 3 6 5 PT 13 315 553 639 Blank plate 102 2 105 7 6 9 PT 14 315 650 73...

Страница 21: ...20...

Страница 22: ...not achieved torque increase air pressure Fastener sheared or thread stripped Gear train or air motor is damaged return for repair GLOSSARY OF TERMS Word or Term Meaning Air pressure graph Graph to s...

Страница 23: ...TOOLS INC 36400 Biltmore Place Willoughby Ohio 44094 USA Tel 1 866 667 2279 Email inquiry norbar us NORBAR TORQUE TOOLS PTE LTD 194 Pandan Loop 07 20 Pantech Business Hub SINGAPORE 128383 Tel 65 6841...

Отзывы: