Содержание Ultium EMG Analog Input SmartLead

Страница 1: ...Analog Input SmartLead P 811 Rev B May 2019 1 Ultium Biomechanics Research System Analog Input SmartLead User Manual...

Страница 2: ...guration 13 7 Pre Use Check Out 19 7 1 Normal Appearance of Signals 19 8 Operating Instructions 20 8 1 Safety Information Summary 20 8 2 Normal Functions with Interface to a PC 20 8 3 Exceptional Func...

Страница 3: ...put SmartLead P 811 Rev B May 2019 3 15 1 Expected Useful Lifetime 26 15 2 Technical Specifications 26 15 3 Environmental Conditions for Storage and Transport 27 15 4 Ultium Analog Input SmartLead Ope...

Страница 4: ...amedical com No part of this document may be copied photographed reproduced translated or reduced to any electronic medium or machine readable form without prior written consent of Noraxon U S A Inc N...

Страница 5: ...Probe This probe gives users the freedom to select the appropriate sensor for their application 1 2 Contradictions Use of the Ultium system is contra indicated in individuals who have implanted pacema...

Страница 6: ...e Accelerometers Goniometers and Force sensors Ultium Serial Number A unique five character tag used to identify each Ultium Sensor or Ultium SmartLead The members of any Ultium network are determined...

Страница 7: ...their application 4 2 Safety Information Summary Cautions Never use the Ultium Analog Input SmartLead to collect data from a person with an implanted pacemaker Never operate the Ultium Analog Input Sm...

Страница 8: ...2 OR Ultium FootSwitch SmartLead with Exposed Input Wires Part 802 Additional contents not illustrated Ultium Analog Input User Manual part 811A This document 6 2 Component Inputs Outputs and Indicato...

Страница 9: ...cter serial number which identifies each SmartLead 6 3 Signal Source Setup The Analog Input SmartLead is manufactured in two forms Exposed Wires 2 5 mm TRRS Mating Connector Connect Ultium Analog Inpu...

Страница 10: ...to the inner workings of the TRRS Mating Connector This component can be customized to allow the user to collect three separate signals The user shall solder their desired wires to the proper poles If...

Страница 11: ...ensor to the Ultium Analog Input SmartLead The Status LED will flash Violet 3 times if the SmartLead was successfully detected If the LED is solid Yellow see the Troubleshooting section of this manual...

Страница 12: ...oting section of this manual Step 1B Connect the Ultium Analog Input SmartLead to the desired circuitry see below Signal Source Setup 6 5 Device Communication Driver Software Installation No driver in...

Страница 13: ...ick on the icon to start the MR3 software 6 7 Companion Software Configuration Before the Ultium Analog Input SmartLead can be used with the Noraxon Ultium system the companion software must be config...

Страница 14: ...2 Click Detect Sensors in Charger All sensors which you would like to use must be in the charger this will add the SmartLead s to the list of sensors only if the unique SmartLead is connected to thei...

Страница 15: ...u redetect sensors in the hardware configuration every time the SmartLeads are removed from the Ultium sensor redetection is necessary to revert to the use of the sensors EMG functionality This will p...

Страница 16: ...rtLead for use in a recording check the box next to the Analog Input channel If one would like to customize the input from the Analog Input SmartLead designate the signal type and the units refer to t...

Страница 17: ...the Find My Sensor feature may be useful Click the topmost star shown in the above figure If all lights blink white color then they are properly connected If one of the sensors blinks red color the Sm...

Страница 18: ...Analog Input SmartLead P 811 Rev B May 2019 18 Once the sensors have been selected double click on the sensor type for the desired Analog Input channel then select the desired sensor type...

Страница 19: ...onal state In the idle state the STATUS LED will flash blue at a low once per second rate When the sensor is actively measuring a signal the STATUS LED will flash recognizably faster green Quick Testi...

Страница 20: ...Ultium System on a person with an implanted pacemaker Never operate the Noraxon Ultium System within 1 meter of any critical medical device 8 2 Normal Functions with Interface to a PC When used with...

Страница 21: ...or Power touch button on the Receiver to power all sensors off 8 5 Storage and Protecting Between Usages For extended storage or when travelling Place all sensors into the sensor docking station and p...

Страница 22: ...Leads Do not immerse Ultium Sensors or SmartLeads in any water or liquid 11 Maintenance 11 1 Device Software firmware updates The internal program firmware inside the various Ultium devices can be upd...

Страница 23: ...backup of the data folders to a separate drive as a precaution Click on the Patch Update link provided in the email or as given on the Noraxon website Download the Patch Update file To install the Pat...

Страница 24: ...updated to support newly designed SmartLeads Make sure you have installed the latest version of MR3 and run a firmware update if needed 12 1 Website Link to FAQ Answers to common questions can be foun...

Страница 25: ...Noraxon USA for further details 13 3 Submitting Technical Support Requests A Support Request can be submitted using the online form available at this link https www noraxon com support learn support r...

Страница 26: ...t may be refused 14 Spare Parts and Consumables 14 1 Consumable Items There are not any consumable items for this product 14 2 Replaceable Items There are not any replaceable items for this product 15...

Страница 27: ...eric Pressure 70kPa to 107kPa 15 4 Ultium Analog Input SmartLead Operation The Ultium Analog Input SmartLead allows a device with up to 3 analog signals to be used with the Ultium system This sensor g...

Страница 28: ...Analog Input SmartLead P 811 Rev B May 2019 28 The input stages of the 3 input channels include resistor dividers This creates an input impedance of 2 1 Mohms...

Отзывы: