58
EN
EXPLANATION OF THE CODES DISPLAYED ON THE SCREEN
PROBLEM
POSSIBLE CAUSE
SUGGESTED REMEDY
E0
Sensor circuit is broken or
shorted.
Replace or connect the sensor.
E1
Voltage input is low.
Check the battery voltage or adjust
the battery monitor level (“H1”, “H2”,
“H3”).
E2
Ventilating fan problem.
Check if the ventilation fan is blocked
or shorted.
E3
Compressor started self-
protection.
Disconnect the device from the
power supply for 30 minutes, and
then restart the device.
E4
Compressor protects itself
against unusual running speed.
Change the operating mode via the
control panel on the device.
E5
Control panel’s overheating
warning
Move the device to a place with
a well-ventilated installation
environment.
TECHNICAL DATA
Connection voltage
DC
12/24 V
(negative earth)
AC
220-240 V~, 50 Hz
Rated current
DC 12/24 V
5.4/3.1 A
AC
0.8 A
Length
DC connection cable
(approx.) 3.5 meters
AC power cord
(approx.) 1.5 meters
Insulation blowing gas
C5H10
Materials
Polypropylene (case), high quality of polyurethane full
foam, CFC-free (insulation)
Weight
16 kg
GENERAL PRODUCT PARAMETERS
Parameter
Value
Parameter
Value
Overall
dimensions
(millimetre)
Height
485
Total volume (dm
3
or l)
52
Width
726
Depth
420
EEI(%)
125
Energy efficiency class
F
Airborne acoustical noise
emissions (dB(A) re 1 pW)
48
Airborne acoustical noise
emission class
D
Annual energy
consumption (kWh/a)
200
Climate class:
SN/N/ST/T