PROBLEM
POSSIBLE CAUSE
SUGGESTED REMEDY
There is water
inside.
The moisture in the air,
trapped inside the cooler,
condenses to water when
the temperature inside the
cooler falls.
The cooler is not defective. Wipe it
out with a dry cloth if necessary.
The compressor
cooler has stopped
operating. The
power LED does
not glow.
The power lead connections
could be loose or dirty at
the compressor cooler or
power supply end.
Check that the compressor cooler
power lead connections have not
become loose or disconnected.
Check that the electrical contacts
have not become dirty and are
preventing full voltage flow to the
compressor cooler.
The compressor
cooler compressor
has stopped
operating.
The compressor cooler has
reached the desired target
cabinet temperature.
The compressor cooler is operating
correctly. No action is required.
The compressor
cooler has stopped
operating.
The internal battery
protection system has
caused the compressor
cooler to switch off because
the battery voltage is low.
The compressor cooler will
automatically restart once the
restart voltage is reached.
The compressor
cooler does not
cool or has stopped
operating.
There may be an internal
fault within the compressor
cooler.
This can only be repaired by an
authorised compressor cooler
service agent.
The compressor
cooler stops and
starts or runs
erratically.
The internal battery
protection system may be
causing the compressor
cooler to switch off because
the battery voltage is low.
Check whether the voltage supply
at the compressor cooler plug has
dropped below the shut down
voltage listed in section “Battery
monitor adjustment with anti-low
voltage protection system”.
The compressor
cooler is running
too long and is not
cooling properly.
Good compressor cooler
performance, especially in
hot ambient temperatures,
is dependent on good
air flow around the
compressor cooler cooling
slots.
Check that all ventilation slots are
unobstructed and there is enough
clearance for good airflow around
the compressor cooler.
An error code is
displayed on the
screen, the machine
is not cooling down.
Check “Explanation of the
codes displayed on the
screen”.
This defect can only be repaired by
an authorized service centre.