14
6.6
Main Lift Sensor Installation
Figure 11: Main Lift Bracket Assembly
1.
There are a variety of ways to mount the main lift bracket on most sprayers. The bracket
should position the sensor approximately in the center of the sprayer, forward of the
boom. An example of this mounting is illustrated in
Figure 12
.
2.
Mount the ultrasonic sensor to the main lift bracket. Run the sensor cable down the center
of the main lift bracket tube.
Figure 12: Example Mounting of the Main Lift Bracket
Avoid mounting the main lift sensor over or near a wheel-track. Measurements
from the wheel-track do not provide an accurate crop height and will cause
measurement and control error.
Ensure the bracket does not collide with any other part of the sprayer throughout
the full range of main lift motion.
Содержание UC5 Sx275
Страница 1: ...Versatile Sx275 Installation Manual VS01 ...
Страница 7: ...4 4 Kit Parts 4 1 Kit Overview Figure 2 VS01 System Parts ...
Страница 8: ...5 4 2 Hydraulic Plumbing Figure 3 VS01 Hydraulic Plumbing ...
Страница 31: ...28 12 3 ITEM C03 43210 03 CABLE UC5 NETWORK 18 AWG 3M 12 4 ITEM C04 43210 01 CABLE UC5 NETWORK 18 AWG 1M ...
Страница 32: ...29 12 5 ITEM C05 43210 20 CABLE UC5 NETWORK 18 AWG 20M 12 6 ITEM C10 43230 04 CABLE UC5 VALVE DT TO DT ...
Страница 33: ...30 12 7 ITEM C20 43240 01 CABLE UC5 INTERFACE TILT DT ...
Страница 34: ...31 12 8 ITEM C21 43240 07 CABLE UC5 INTERFACE MAIN DT WITH AUX 1 2 ...
Страница 35: ...32 12 9 ITEM C30 43250 04 CABLE UC5 BATTERY AMP FUSED 5A ...