Hydraulic Installation
Ensure all pressure has been bled from the system before disconnecting any lines
or fittings. Hydraulic pressure will exist on the wing tilt circuits unless the wings
are being supported by other means. The hydraulic installation may be performed
with the wings in transport position, resting on the ground or with the tilt cylinders
fully extended.
Component failure due to oil contamination is not covered under the NORAC UC5
system warranty. It is recommended that a qualified technician perform the
hydraulic installation.
8.1
Valve Assembly
1.
On a clean surface remove the plastic plugs from the block.
2.
Install the 6MB 6MOR (F07) fittings into the “P” and “T” ports. Tighten to 18 ft-lbs (24
Nm).
3.
Insert the two orifices (F09) into the “B” ports of the two stations closest to the “P” and
“T” ports with the notch facing out.
4.
Install the 6MB 6MOR (F07) fittings into the “B” ports. Tighten to 18 ft-lbs (24 Nm).
5.
Install the 6MBP (F08) plugs into the “A” ports of the two stations closest to the “P” and
“T” ports. Tighten to 18 ft-lbs (24 Nm).
6.
Install the orifice (F09) into the “A” port of the 3
rd
station (furthest from the “P” and “T”
ports) of the block.
7.
Install the orifice (F17) into the “B” port of the 3
rd
station of the block.
8.
Install the 6MB 6MOR (F07) fittings into the “A” and “B” ports of the 3
rd
station of the
block. Tighten to 18 ft-lbs (24 Nm).
Содержание UC5 Can Bus
Страница 1: ...Rogator Active Roll 2012 Installation Manual RG12 ...
Страница 7: ...4 4 Kit Parts 4 1 Kit Overview Figure 2 RG12 System Parts ...
Страница 8: ...5 4 2 Hydraulic Plumbing Figure 3 RG12 Hydraulic Plumbing ...
Страница 21: ...18 Figure 13 Control Module and Electrical Box Location ...
Страница 35: ...32 11 3 ITEM C05 43210 15 CABLE UC5 NETWORK 18 AWG 15M 11 4 ITEM C10 43230 04 CABLE UC5 VALVE DT TO DT ...