background image

 

  

 
 

Canada 

NORAC Systems International Inc. 

Phone: (+1) 306 664 6711 

Toll Free: 1 800 667 3921 

Shipping Address: 

3702 Kinnear Place 

Saskatoon, SK 

S7P 0A6 

 

 

 

United States 

NORAC, Inc. 

Phone: (+1) 952 224 4142 

Toll Free: 1 866 306 6722 

Shipping Address: 

6667 West Old Shakopee Road, Suite 111 

Bloomington, MN 

55438 

 

 

 

Europe 

NORAC Europe 

Phone: (+33) (0)4 26 47 04 42 

Shipping Address: 

Rue de l’hermitage 

01090 GUEREINS  

France  

 

 

 

www.norac.ca

 

Содержание Case AFS Pro 600

Страница 1: ...Spray Height Controller Case AFS Pro 600 Display Kit Installation Manual PRO600 ...

Страница 2: ...ems International Inc reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously Every effort has been made to ensure the accuracy of the information contained in this manual The technical information in this manual was reviewed at the time of approval for publication ...

Страница 3: ...Installation 4 3 CABLE DRAWINGS 5 3 1 ITEM C01 43220 01 CABLE UC5 NETWORK 14 AWG 1M 5 3 2 ITEM C30 43250 14 CABLE UC5 BATTERY 2 PIN DT 5 3 3 ITEM C25 44602 01 SWITCH REMOTE HAND CONTROL 6 3 4 ITEM C26 43240 26 CABLE UC5 SWITCH BOX 7 3 5 ITEM C40 43260 07 CABLE UC5 CAN BUS 3 PIN DT J1939 8 APPENDIX A ALTERNATE CONFIGURATION 9 ...

Страница 4: ...ion Before you connect the UC5 to the Case AFS Pro 600 you must ensure that you have the latest Pro 600 software installed The Pro 600 software must be Version 25 or newer 1 2 List of Parts Item Part Number Name Quantity C01 43220 01 CABLE UC5 NETWORK 14 AWG 1M 1 C25 44602 01 BOX SWITCH UC4 REMOTE HAND CONTROL VER 1 RMR 1 C26 43240 26 CABLE UC5 INTERFACE SWITCH BOX 1 C30 43250 14 CABLE UC5 BATTERY...

Страница 5: ... pin Deutsch connector located on the center section of the boom at the rear of the sprayer 3 Connect the Deutsch plug on cable C40 to the end of the control module with only one Deutsch connector 4 Connect the power cable C30 to one of the two CANbus connectors on the control module Connect the 2 pin DT connector on C30 to a 15A 12 VDC source 5 Connect cable C01 to the other CANbus connector and ...

Страница 6: ...n the Input Module 3 Connect the 12 pin Deutsch plug on C26 to the grey end connector on the input module Route the other end of the cable to the hitch of the sprayer pull type or to the cab self propelled 4 Attach the switch box C25 inside the cab and connect it to cable C26 An extra label is provided with the switch box if you prefer to remove the switches from the housing and mount them in the ...

Страница 7: ...5 3 Cable Drawings 3 1 ITEM C01 43220 01 CABLE UC5 NETWORK 14 AWG 1M 3 2 ITEM C30 43250 14 CABLE UC5 BATTERY 2 PIN DT ...

Страница 8: ...6 3 3 ITEM C25 44602 01 SWITCH REMOTE HAND CONTROL ...

Страница 9: ...7 3 4 ITEM C26 43240 26 CABLE UC5 SWITCH BOX ...

Страница 10: ...8 3 5 ITEM C40 43260 07 CABLE UC5 CAN BUS 3 PIN DT J1939 ...

Страница 11: ...or Pin Location Connector Pin Location Power White Grey End C26 1 Grey End C26 1 Ground Black Grey End C26 12 Grey End C26 12 Remote Auto Brown Grey End C26 11 Grey End C26 11 Remote Manual Blue Grey End C26 10 Grey Side C20 4 Main Up Purple Grey End C26 9 Grey End C26 9 Main Down Yellow Grey End C26 8 Grey End C26 8 Roll CW Red Grey Side C20 3 Grey End C26 6 Roll CCW Orange Grey Side C20 4 Grey E...

Страница 12: ... 3702 Kinnear Place Saskatoon SK S7P 0A6 United States NORAC Inc Phone 1 952 224 4142 Toll Free 1 866 306 6722 Shipping Address 6667 West Old Shakopee Road Suite 111 Bloomington MN 55438 Europe NORAC Europe Phone 33 0 4 26 47 04 42 Shipping Address Rue de l hermitage 01090 GUEREINS France www norac ca ...

Отзывы: