nora
®
pro steamer
nora systems
, Inc.
·
9 Northeastern Blvd.
·
Salem, NH 03079
BEFORE USING THE STEAM GENERATOR, READ AND FOLLOW THIS INSTRUCTION MANUAL.
PLEASE READ THE SAFETY INSTRUCTIONS ON THIS HANDBOOK BEFORE PROCEEDING
WITH THE FIRST USE.
Attention!! Use only distilled water
Attention!! Hot surface
Attention!! Steam... burning danger
SAFETY REGULATIONS
The electric supply connection shall be made by a qualified electrician
and comply with IEC 60364-1.
It is recommended that the electric supply to this machine should include
either a residual current device that will interrupt the supply if the leakage
current to earth exceeds 30ma for 30ms or a device which will prove
the earth circuit and the outlet used should be grounded. Do not use
extension cords.
SAFETY VALVE
This machine is equipped with two safety valves, able
to ensure the safety of the machine itself in case other primary control
devices are inefficient (due to a failure). Due to the extreme importance
of these components and as not to compromise the safety of the machine,
it is recommended to provide to check them and to substitute them
through an authorized service center every 2 years starting from the
purchasing date. For parts & service, please contact nora technical
dept. 1-800-336-5096.
PRESSURE SWITCH
This machine is equipped with a pressure switch
able to check and to maintain the pressure under certain preset limits (ref.
“rated pressure” on the technical label underneath the machine). In case
there would be a steam leakage on the lower side of the machine, it
means that the functioning of this device has been compromised and the
safety valve has been involved as to limit the boiler’s internal pressure.
It is recommended not to use the ma chine, immedia tely unplug
the machine from the power feeding and call the service center.
MUD DRAIN FROM THE BOILER
The machine is equipped with a
warning system “mud drain”. The writing CALC will appear on the display
to indicate that it is necessary to proceed with the boiler cleaning.
The opening of the drain cap has to be strictly carried out when the
machine has been switched off (plug not inserted) for at least 5 hours.
See Maintenance of steam cleaner in this guide.
ATTENTION.
Do not use the appliance within the range of persons
unless they wear protective clothing.
ATTENTION.
The high pressure jets can be dangerous if not used
properly. The jet does not have to be directed against persons, elec-
trical devices under tension or the unit itself.
Do not direct the jet against yourself or others in order to clean clothes
or footwear. Disconnect power before effectuating maintenance on
user’s responsibility. This machine is not intended for use by persons
(including children) with reduced physical, sensory or mental capabili-
ties, or lack of experience and knowledge. Monitor the children so
they cannot play with the machine. To ensure the machine’s safety, use
only original spare parts from the manufacturer or spare parts approved
by the manufacturer. For parts & service, please contact nora technical
dept. 1-800-336-5096.
ATTENTION.
Pressure hoses, fitting and couplings are important for the
safety of the machine. Use only those recommended by the manufacturer.
Do not use the machine if the power cord or other important parts of
the machine are damaged, i.e. safety devices, pressure hoses and trig-
ger gun. The hand-arm vibration data, referred to this device, are not
mentioned as they are below 2.5 m / s ².
Technical data - Generator
EU: nora pro steamer
Version 230 V
US: nora pro steamer
Version 120 V
Steam boiler
AISI 304 stainless steel (with heating element which can be replaced)
Chassis
Upper and lower housing: P04 steel
Steam boiler volume
I
1,5
Water tank
I
3
Working pressure
bar/kPa
8
800
Permissible Steam Pressure
bar/kPa
12
1200
Max.
Steam production
Kg/h
3,8
2,64
Max.
Steam T
o
o
C/
o
F
174
o
C
345
o
F
Kickback forces
N
< 20
Voltage
V-Hz
230 – 50/60
120 – 50/60
Maximum output
kW
2,45
1,65
Steam boiler output
kW
2,4
1,6
Power cable
m/feet
5
16,4
Mass
kg/lb
15
33
06/2016