2

Declaration of Conformity with FCC and Canadian Ministry of Health Rules for 

Electromagnetic Compatibility 

• Nonin Medical, Inc., of 13700 1st Avenue North, Plymouth, Minnesota, 55441, declares under its sole 

responsibility that Model 9560, to which this declaration relates, comply with part 15 of the FCC Rules. Operation 
is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device 
must accept any interference received, including interference that may cause undesired operation. 

• Ministry of Health (Canada), Safety Code 6: standards include a substantial safety margin designed to ensure 

the safety of all persons, regardless of age and health. The exposure standard for wireless mobile phones 
employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC 
is 1.6W/kg. 

Federal Communications Commission (FCC) Notice 

This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a 
residential installation. This equipment generates, uses, and can radiate radio frequency energy. If not installed 
and used in accordance with the instructions, it may cause harmful interference to radio or television reception, 
which can be determined by turning the equipment off and on. The user is encouraged to try to correct the 
interference by one or more of the following measures: 
• Reorient or relocate the receiving antenna. 
• Increase the distance between the equipment and the receiver. 
• Connect the equipment to an outlet on a circuit different from the outlet where the receiver is connected. 
• Consult the dealer or an experienced radio/TV technician for assistance. 
• RF Exposure: For body worn operation, to maintain compliance with FCC RF exposure guidelines, use only 

accessories that contain no metallic components and provide a separation distance of 15 mm (0.6 inches) to the 
body. Use of other accessories may violate FCC RF exposure guidelines and should be avoided. 

• The Model 9560 is designed and manufactured not to exceed the emission limits for exposure to radio frequency 

(RF) energy set by the United States FCC. These limits are part of comprehensive guidelines and establish 
permitted levels of RF energy for the general population. The guidelines are based on the safety standards 
previously set by both U.S. and international standards bodies. This EUT has been shown to be capable of 
compliance for localized specific absorption rate (SAR) for uncontrolled environment/general population 
exposure limits specified in ANSI/IEEE Std. C95.1-2005 and has been tested in accordance with the 
measurement procedures specified in FCC/OET Bulletin 65 Supplement C (2001) and IEEE Std. 1528-2003.

• The FCC requires the user to be notified that any changes or modifications to this device that are not expressly 

approved by Nonin Medical, Inc. may void the user’s authority to operate the equipment. 

A Guide to Symbols

Symbol

Definition of Symbol

Follow Instructions for Use.

Consult Instructions for Use

!

Caution! 

Type BF Applied Part (patient isolation from electrical shock)

UL Mark for Canada and the United States with respect to electric shock, fire, and mechanical 
hazards only in accordance with IEC 60601-1, UL 60601-1 and CAN/CSA-C22.2 No. 601.1.

0123

CE Marking indicating conformance to EC Directive No. 93/42/EEC concerning medical devices

Radio Equipment Class Identifier

Serial Number

Battery Orientation

Non-ionizing electromagnetic radiation. Equipment includes RF transmitters. Interference may 
occur in the vicinity of equipment marked with this symbol.

Indicates separate collection for electrical and electronic equipment (WEEE).

SN

Содержание Onyx II 9560

Страница 1: ...tional hemoglobin Factors that may degrade pulse oximeter performance or affect the accuracy of the measurement include the following The device may not work when circulation is reduced Warm or rub th...

Страница 2: ...r assistance RF Exposure For body worn operation to maintain compliance with FCC RF exposure guidelines use only accessories that contain no metallic components and provide a separation distance of 15...

Страница 3: ...ch new Model 9560 When batteries are low the numeric displays flash once per second Remove batteries if the device will be stored for more than 30 days Replace low batteries as soon as possible using...

Страница 4: ...the startup sequence the device begins sensing the pulse indicated by the blinking pulse quality indicator Allow the device to stabilize and observe about 4 seconds of continuous green colored pulse...

Страница 5: ...as permanent damage could result 2 Dry with a soft cloth or allow to air dry Ensure that all surfaces are completely dry Testing Summary SpO2 accuracy and low perfusion testing was conducted by Nonin...

Страница 6: ...imately 600 spot checks Storage 12 months minimum Classifications per IEC 60601 1 CAN CSA C22 2 No 601 1 UL 60601 1 Degree of Protection Type BF Applied Part Enclosure Degree of Ingress Protection IP3...

Страница 7: ...l 9560 found to be within specifications Model 9560 is a precision electronic instrument and must be repaired by trained Nonin personnel only Any sign or evidence of opening the Model 9560 field servi...

Страница 8: ...netic environment specified below The customer and or user of this device should ensure that it is used in such an environment Electrostatic Discharge ESD IEC 61000 4 2 6 kV contact 8 kV air 6 kV cont...

Страница 9: ...20 V m 80 MHz to 2 5 GHz 20 V m where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distance in mete...

Отзывы: