Nonin Onyx II 9550 Скачать руководство пользователя страница 5

Table 3: Guidance and Manufacturer’s Declaration—Electromagnetic Immunity

NOTES:

At 80 MHz and 800 MHz, the higher frequency range applies.

These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and 

people.

Table 4: Recommended Separation Distances

The following table details the recommended separation distances between portable and mobile RF communications equipment and this device.

For transmitters rated at a maximum output power not listed above, the recommended separation distance 

in meters (m) can be estimated using 

the equation applicable to the frequency of the transmitter, where 

is the maximum output power rating of the transmitter in watts (W) according to 

the transmitter manufacturer. 

NOTES:

At 80 MHz and 800 MHz, the higher frequency range applies.

These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and 

people.

Immunity Test

IEC 60601 Test Level Compliance 

Level

Electromagnetic Environment—Guidance

This device is intended for use in the electromagnetic environment specified below. 

The customer and/or user of this device should ensure that it is used in such an environment.

Portable and mobile RF communications equipment should be used no closer to any part of the device, including cables,  than the recommended 
separation distance calculated from the equation applicable to the frequency of the transmitter.

Recommended Separation Distance

Conducted RF
IEC 61000-4-6

3 Vrms
150 kHz to 80 MHz

N/A

Radiated RF
IEC 61000-4-3

3 V/m
80 MHz to 2.5 GHz

[3] V/m

[2] V/m

80 MHz to 800 MHz 

800 MHz to 2.5 GHz 

where 

P

 is the maximum output power rating of the transmitter in watts (W) according to 

the transmitter manufacturer and 

is the recommended separation distance in meters 

(m). 

Field strengths from fixed RF transmitters, as determined by an electromagnetic site 
survey

a

, should be less than the compliance level in each frequency range.

b

Interference may occur in the vicinity of equipment marked with the following symbol: 

a.

 

Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur 

radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic envi-
ronment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in 
which the device is used exceeds the applicable RF compliance level above, the device should be observed to verify normal operation. If 
abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the device.

b.  Over the frequency range 150 kHz to 80 MHz, field strengths should be less than [3] V/m.

This device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. Users of this device can help 
prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communication equipment (transmitters) 
and the device as recommended below, according to maximum output power of the communications equipment.

Separation Distance According to Frequency of Transmitter

Rated Maximum Output Power of Transmitter

W

150 kHz to 80 MHz

80 MHz to 800 MHz

800 MHz to 2.5 GHz

0.01

0.12

0.12

0.35

0.1

0.37

0.37

1.11

1

1.2

1.2

3.5

10

3.7

3.7

11.1

100

12

12

35

d

1.17

P

=

d

1.17

P

=

d

3.50

P

=

d

1.17

P

=

d

1.17

P

=

d

3.50

P

=

NONIN

®

 Medical, Inc.

13700 1st Avenue North
Plymouth, MN  55441-5443  USA

+1 (763) 553-9968
800-356-8874 (US and Canada)
Fax +1 (763) 553-7807
E-mail: [email protected]
www.nonin.com

Authorized EC Representative:
MPS, Medical Product Service 
GmbH
Borngasse 20
D-35619 Braunfels, Germany

©2008

5104-001-04

EC REP

Содержание Onyx II 9550

Страница 1: ...ravascular dyes may affect the accuracy of the SpO2 measurement Do not autoclave or immerse this device in liquid or use caustic or abrasive cleaning agents A flexible circuit connects the two halves Do not twist or pull the flexible circuit or overextend the device s spring Do not hang the lanyard from the device s flexible circuit strain relief A functional tester cannot be used to assess the ac...

Страница 2: ...p touches the built in stop guide 2 Make sure the finger is lying flat not on its side and is centered within the device For best results keep the Onyx II at the patient s heart or chest level 3 If the device does not turn on remove the finger and wait a few seconds before reinserting it When a finger is inserted the Onyx II performs a brief startup sequence Verify that all LEDs illuminate during ...

Страница 3: ...o 95 non condensing Altitude Operating Up to 40 000 feet 12 192 meters Hyperbaric Pressure Up to 4 atmospheres Battery Life Continuous Approximately 2 500 spot checks based on 21 hours of operation using two AAA size alkaline batteries calculated at 30 seconds per spot check Battery Life Storage 4 years minimum Classifications per IEC 60601 1 CSA 601 1 UL 60601 1 Degree of Protection Type BF Appli...

Страница 4: ... use in the electromagnetic environment specified below The customer and or user of this device should ensure that it is used in such an environment Electrostatic Discharge ESD IEC 61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material relative humidity should be at least 30 Electrical Fast Transient Burst ...

Страница 5: ...is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site surveya should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones an...

Отзывы: