Section 10: Troubleshooting
Read the instruction manual and
herbicide label carefully before
using the Frontline Classic.
Please Note:
Nomix Enviro reserves
the right to change specifications
and availability without notice.
Limits on warranties and liabilities
as well as necessary cautions are
on the product labels. Nomix and
Nomix Enviro are trademarks of
Frontier Agriculture Ltd.
For further information contact
Nomix Enviro on 01264 388050.
23
Symptom
Potential Problem
Solution
Head drips
when lance
is in the off
position
• Air bubble in the lance
• Valve sticking open
• Reprime lance
• Contact Nomix
Enviro
Head drips
when lance
is in use
• Disc not fitted
• Disc not spinning
• Too much herbicide
reaching disc
• Refit disc
• Make sure battery
is charged
• Recalibrate
No beeper
sound
• Low battery
• Pacer switched off
• Mechanism failure
• Charge battery
• Switch pacer on
• Contact Nomix
Enviro
Disc will not
turn
• Battery not connected
• Battery not charged
• Motor problem
• Connect battery
• Charge battery
• Contact Nomix
Enviro
No or low
herbicide
flow
• Valve/inline hose
blocked with dried
chemical
• Thick herbicide
• Set head to Prime
and follow cleaning
procedure
• Follow cleaning
procedure and
shake herbicide
pack for a
minimum of 2
minutes
Debris
around disc
• Requires cleaning
• Remove disc using
disc ejector tool,
check alignment,
clean and replace
Spray disc
does not fit
• Disc damaged
• Replace with new
disc