![Nome nmas Simple Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/nome/nmas-simple/nmas-simple_user-manual_1700010009.webp)
nmas Simple
Picture 5: Figure is higher than alarm level in three subsequent measurements and alarm is
not triggered with count-up value of five.
Nmas Hardware
nmas Simple
In nmas Simple hardware components Sensor Unit (SU) and Local Data (LD)
are combined in one housing. Other hardware components can be added as
external units.
Nmas Hardware Components
SU (Sensor Unit)
Sensor Unit (nmas SU) is used to measure data from different kinds of sensors.
Data can be vibration sensor data or data from any other sensor providing
signal between 0 - 30 VDC. Data can be processed inside unit to enable
characteristic value outputs. SU uses Ethernet or radio for communication.
Unit can be configured for different measurements. Configuration is stored in
LD.
LD (Local Data)
Local Data (nmas LD) is a unit to locally store and display measurement data.
LD can store up to 500 MB of measurement data. This is usually more than six
months of measurements.
Data samples from nmas SU are stored as raw signals. Also selected
characteristic values are stored for faster analysis. All raw signals can be
downloaded and processed for more accurate analysis afterwards.
When database is coming to it's size limitations cleaner activates and removes
parts of oldest data.
nmas LD communicates to nmas SU with wired Ethernet or wireless radio
(special orders).