NOMA 052-8398-2 Скачать руководство пользователя страница 2

 

IMPORTANT: RETAIN FOR FUTURE REFERENCE, AND READ CAREFULLY.

           Toll Free 1-866-827-4985 model no. 052-8398-2

 

Warning:

 To risk of personal injury, do not bend the blade arms (also referred to as flanges) or the brackets while 

balancing the blades or cleaning the fan.  Do not insert foreign objects between rotating fan blades. 

 

 

   

 

   

 

 

 

 

 

   

 

  

 

 

Warning: 

for fan support” 

with the screws provided with the outlet box.

To reduce the risk of fire, electric shock, and personal injury, mount fan to outletbox marked ”acceptable 

 

 

 

   

 

 

   

 

 

 

 

 

 

 

 

 

 

Safety Rules – Read and Save These Instructions

     before beginning.

 

2.  All wiring must be in accordance with the national and local electrical codes. Electrical installation should 
     be performed by a qualified licensed electrician. 

 

 

3.  

WARNING:

 

To reduce the risk of electric shock or fire, do not use this fan with any solid-state fan-speed 

 control device.  It will permanently damage the electronic circuitry.   

4. 

 

CAUTION: 

 To reduce the risk of personal injury, use only the screws provided with the outlet box.

5.  The outlet box and support structure must be securely mounted and capable of reliably supporting a 
     minimum of 35 lb (15.9 kg).

 

Use only UL listed outlet boxes marked “FOR FAN SUPPORT.”

 

6.  The fan must be mounted with a minimum of 7' (2.13 m) from the trailing edge of the blades to the 
      floor.
7.  Avoid placing objects in the path of the blades.

8.  To avoid personal injury or damage to the fan and other items be cautious when working around or 
     cleaning the fan. 
9.  Do not use water or detergents when cleaning the fan or fan blades.  A dry dust cloth will be suitable for 
     most cleaning.    

      

                     
                                       

10. After making electrical connections, spliced conductors should be turned upward and pushed carefully 
      up into the outlet box. The wires should be spread apart with the grounded conductor and the 
      equipment-grounding conductor on one side of the outlet box and the ungrounded conductor on the 
      other side of the outlet box.

 

 

11. All set screws must be checked and retightened where necessary

 

                     before installation.

Warning:

 

To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked "acceptable for 

fan support of 35 lb (15.9 kg) or less" and use mounting screws provided with the outlet box. Most outlet boxes   

 

                                   

commonly used for the support of light fixtures are not acceptable for fan support and may need to be replaced. 

Due to the complexity of this fan, a qualified licensed electrician is strongly recommended. 

 

!

!

!

Attention: 

This product is equipped with a 190 W limiting device. If lamping exceeds 190 W the light kit will shut 

bulbs with the correct wattage, and then turning the light kit back on.  

 

                          

   

 

 

!

   

 

 

Содержание 052-8398-2

Страница 1: ...Hanson LED C e i l i n g F a n OWNER S MANUAL Toll free 1 866 827 4985 IMPORTANT For your safety please read and understand this manual before installing or operating this product model no 052 8398 2...

Страница 2: ...unted with a minimum of 7 2 13 m from the trailing edge of the blades to the floor 7 Avoid placing objects in the path of the blades 8 To avoid personal injury or damage to the fan and other items be...

Страница 3: ...amage ensure that the hanging location allows the blades a clearance of 7 2 13 m from the floor and 30 76 cm from any wall or obstruction This fan can be mounted with a downrod on a regular no slope o...

Страница 4: ...pcs 6 pcs 1 pc 14 Hardware bag Blade screws 16 pcs 16 pcs Fibre washers Wood screws 2 pcs 2 pcs 2 pcs Flat washers 2 pcs Spring washers Mounting screws Installing Mounting Bracket Note Do not Mount d...

Страница 5: ...through canopy and downrod stand cover and pull lead wires through downrod Fig 2a 2 Securing assembly Insert downrod into downrod coupling Make sure to align holes in downrod with the hole in the cou...

Страница 6: ...licensed electrician for advice They must be grounded for safe opetration 8 Lift fan onto the mounting bracket Turn housing until hanging ball seats itself into ball socket listen for click For added...

Страница 7: ...re from the mounting bracket and hanger ball to the ground wire bare or green from the outlet box Outlet box mains cables Ground wire Green ground wire from mounting bracket and hanger ball AC IN L LA...

Страница 8: ...se until tight Fig 6 Canopy Cover Canopy 7 Assemble blade arm to blade with blade screws Fig 7 8 If there are plastic tabs shaped like bottle caps remove and discard them These are stabilizers that pr...

Страница 9: ...H CODE SWITCH Codes are set by pushing dip switches up or down It is imperative that the code used for both transmitter and receiver is exactly the same otherwise remote controller will not work Pleas...

Страница 10: ...ather to re circulate air Fig 13 Forward and reverse direction function This ceiling fan is equipped with reverse switch for downward or upward air flow NOTE Do not change the direction of rotation th...

Страница 11: ...ight Make sure wire nut connections are not ra the switch housing Allow a 24 hour breaking in period Most noises associated with a new fan disappear during this time If using ceiling fan light kit mak...

Отзывы: