![Nokia RH-47 Series Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/nokia/rh-47-series/rh-47-series_rf-description-and-troubleshooting_1699395021.webp)
Nokia Customer Care
7 - RF Description and Troubleshooting
Company Confidential
RH-47
Issue 1 05/04
Copyright
©
2004 Nokia Corporation
Page 21
Company Confidential
Select
Band
GSM850 or GSM1900
Active unit
RX
Operation mode
Continuous
RX/TX Channel
190 or 661
Please refer to the fault-finding chart and Appendix C for proper levels at different test
points.
Measuring analogue RX I/Q signals using oscilloscope
Measuring with an oscilloscope on “RXIINN” or “RXQINN” is recommended only if RSSI
reading does not provide enough information. There are dedicated test points for RX I
and Q signals. Apply an Input signal level of -80dBm.
1 Start Phoenix Service Software and open FBUS connection:
Select
Scan Product
Ctrl-R
Wait until phone information is shown in the lower right corner of the screen.
2 Set operating mode to local mode:
Select
Maintenance
Alt-M
Testing
T
RF Controls
F
Wait until the RF Controls window is pops up.
3 In the RF Controls window:
Select
Band
GSM850 or GSM1900
Active unit
RX
Operation mode
Continuous
RX/TX Channel
190 or 661
AGC
14
Following picture should be displayed on an oscilloscope' s screen if the GSM850