Nokia Customer Care
7 - RF Description and Troubleshooting
Company Confidential
RH-47
Issue 1 05/04
Copyright
©
2004 Nokia Corporation
Page 13
Company Confidential
RF test points
The RF power supplies are generated in the UEM and can be measured either in the
Mjoelner chamber or in the base band chamber. On the drawing below small circles show
the locations of the test points.
1900 Rx SAW (Z603)
4511325
Murata
850 Tx SAW (Z701)
4511317
Murata
850 Rx SAW (Z604)
4511323
Murata
Antenna switch (Z601)
LMZ0170
4510449
Murata
Crystal (B601)
TSX-8A-25850
4510337
Toyocom
Tx Coupler (L801)
LDC21836M19D-185
4550197
Murata
Tx850 buffer (V802)
BFR949T-E6327
4210171