![Nokia RH-47 Series Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/nokia/rh-47-series/rh-47-series_rf-description-and-troubleshooting_1699395019.webp)
Nokia Customer Care
7 - RF Description and Troubleshooting
Company Confidential
RH-47
Issue 1 05/04
Copyright
©
2004 Nokia Corporation
Page 19
Company Confidential
Select
Maintenance
Alt-M
Testing
T
RF Controls
F
Wait until the RF Controls window pops up.
3 In the RF Controls window:
Select
Band
GSM850 or GSM1900
Active unit
RX
Operation mode
Burst
RX/TX Channel
190 or 661
Select
Maintenance
Alt-M
Testing
T
SNR Measurement
M
Select Both
(Radio
Button)
The setup should now look like this:
4 Press the Start button.
5 To continue, follow the instructions in the following pop-up windows.
6 Connect an external signal generator to the RF connector of the phone and set