PAMS
Technical Documentation
NSC/W–1/3
Disassembly & Troubleshooting Instructions
Page 14
Original 11/99
Power doesn’t stay on, or phone is jammed
If this kind of fault has come after flash programming, there are most prob-
ably open pins in ICs.
The soldered joints of ICs: D202 (MAD1), D201 (FLASH), N150 (CCONT),
D200 (SRAM) are useful to check first.
Normally the power will be switched of by CCONT (N150) after 30 seconds,
if the watchdog of the CCONT can not be served by software.
The watchdog updating can be seen by oscilloscope at pin 50 (DataselX) of
CCONT.
In a normal case there is a short pulse from ”1” –> 0 every 8 seconds.
The power off function of CCONT can be prevented by connecting a short
circuit wire from CCONT pin 29 to ground.