NKC-1X
System Module
CCS Technical Documentation
Page 26
Nokia Corporation
Issue 1 02/03
System Connector Lines
Battery Connector Lines
BSI and BTEMP lines are protected by spark gaps and the RC-circuit (4k7 & 10n), in
which the resistors are size 0603.
MBUS and FBUS
The opening in the protective metal deck, underneath the battery, is so small that ESD
does not get into the MBUS and FBUS lines in the production test pattern.
Table 4: System Connector lines
System Connector signals that have EMC protection
Protection type
VIN
XMIXP
XMICN
XEARP
XEARN
HEADINT
MICP
ferrite bead (600
/199MHz)
X
X
X
X
X
ferrite bead (420
/100MHz)
X
spark gaps
X
X
X
X
X
X
PWB capacitors
X
X
X
X
X
X
RC-circuit
X
X
X
X
X
capacitor to
ground
X
X
X
X
X
Содержание NKC-1X Series
Страница 1: ...CCS Technical Documentation NKC 1X Series Transceivers Issue 1 02 03 Nokia Corporation System Module ...
Страница 28: ...NKC 1X System Module CCS Technical Documentation Page 28 Nokia Corporation Issue 1 02 03 ...
Страница 29: ...CCS Technical Documentation System Module NKC 1X Issue 1 02 03 Nokia Corporation Page 29 70mAmax ...
Страница 32: ...NKC 1X System Module CCS Technical Documentation Page 32 Nokia Corporation Issue 1 02 03 ...
Страница 33: ...CCS Technical Documentation System Module NKC 1X Issue 1 02 03 Nokia Corporation Page 33 ...
Страница 34: ...NKC 1X System Module CCS Technical Documentation Page 34 Nokia Corporation Issue 1 02 03 ...
Страница 54: ...NKC 1X System Module CCS Technical Documentation Page 54 Nokia Corporation Issue 1 02 03 ...