Figure 16 General voltage checking test points (main board, bottom side)
Selftest troubleshooting
RF selftests
Prerequisites
Do a hardware initialization before you start the selftests:
Testing
→
GSM
→
RF Controls
→
RX and then press Stop.
Context
Note:
The RF connector should be terminated to 50 Ohms or connected to the antenna. Check this
carefully before performing the self tests.
Note:
The phone should be in local mode when performing Self tests
RM-352; RM-354
RF troubleshooting
Page 4 –8
COMPANY CONFIDENTIAL
Issue 1
Copyright © 2008 Nokia. All rights reserved.