CONFIDENTIAL
15 (30)
NSE-5
Service & Analysis Center Europe
Repairhints
Version 1.0 Approved
SACE AMS Training Group
30.07.2000
Repairhints_nse5_002508
Checked by:
AMS TRAINING GROUP
Approved by:
SACE
NOT CHARGING (APPEARS IN DISPLAY,- & ERRORBEEP)
Energy management
calibration
Battery temperature
failed
Battery size failed
Battery voltage failed
Charge current failed
Charge voltage failed
Try to charge after
calibration
Check X101 values at
R115/123. Change N100
Check X102 values at
R115/123. Change N100
Change N100
Check R102, change
N100/101
OK
not OK
not OK
not OK
not OK
Check V_CHAR on voltage
devider R103/104
Change N100
Check F100,R100, change
N101
OK
"Not charging" -appears
on display-& errorbeep
not OK
notOK
Failure
messages