CONFIDENTIAL
14 (30)
NSE-5
Service & Analysis Center Europe
Repairhints
Version 1.0 Approved
SACE AMS Training Group
30.07.2000
Repairhints_nse5_002508
Checked by:
AMS TRAINING GROUP
Approved by:
SACE
NOT CHARGING ( NOTHING HAPPENS IF CHARGER IS CONNECTED )
First of all : Always Check the mechanical condition of all connectors and connections
Not charging
Check voltage level at R104-
if it is higher than 0,4V when
charger is connected
Check/change N100
Check/change R102/103/104,
F100, X101/102/200,
N101, C101/144,R101 (soldering,
electrical and mechanical
condition)
PCB faulty
lower 0,4V
OK
>0,4V
notOK