Power supply 12...32 VDC
(Green connector)

or  85...240 VAC
(Grey connector)

The field display series is modular and easy to as-
semble according to customers wishes. The basic
construction consists of mother board with tree slots,
A, B and C. Slot A determines meter type and provides
always input signal. Slot B and C are interchangeable.
As factory delivery input signal is always installed into
slot A , mA output into slot B and alarms into slot C. In
case of  f.ex 4 alarms and relay card with 2 change-over
contact (2 + 2 relays) are  used, you must place second

Slots  A-C

Change of meter
type:

Input card is placed always to
slot A. By changing input card
you can get an other type of
meter. You can change meter
with pulse input to meter with
current input, thermocouple,
strain gage etc.

Additional slots:

Additional cards provide output
4..20 mA, alarms, serial inter-
face, BCD output etc. Meter
data sheet dictates possible
combinations. grey connectors
allow line voltage 110..240  VAC
(relay contacts).

Power supply:

There are two different mother
boards power supply 85..240
VAC and 12..32 VDC. VDC-
mother board accepts
24 VAC. Connectors are colour
coded.

relay card into slot B. If you accept only closing  or
opening relay contacts, you need only one relay card
with 4 relays placed into slot  C. The slot B is now
usable for  other optional outputs.
You can have different types of meters  by only
changing the input card in slot A. Data sheet of each
type of meter dictates the possible combinations.
Recalibration of card is not needed; only scaling and
other settings  must be set by front panel keys.

All cards have calibration
memory

Control electronic case:

Construction of field display series

Содержание 1000F-2071

Страница 1: ...1 Manual Model 575F 2071 1000F 2071 1100F 2071 and 1800X 2071 Serial input RS232 RS485 No 290507 Nokeval...

Страница 2: ...meters 4 Case dimensions 4 Configuration 5 Serial protocol SCL 6 Counting check sum 6 Example of control message without BCC 6 XOR function without calculator 7 Non addressable ASCII protocol 7 Displa...

Страница 3: ...okeval SCL protocol where only the address value and check sum are sent The displays come standard with both the serial inputs RS 232 and RS 485 The serial bus is galvanically isolated from the proces...

Страница 4: ...econds Specified instructions on pages 6 7 Configuration Resetting configuration parameters Some times it is necessary to return indicator parameters to factory defaults e g if secret access code is m...

Страница 5: ...ddressable SCL or non addressable ASCII Baud Baud rate selection 300 600 1200 2400 4800 9600 19200 Addr Serial address 0 127 SCL only Bcc Checksum selection ON used SCL only Resp Responce message sele...

Страница 6: ...ost significant bit is set If you want to command a device in address 4 the ID byte will be 132 or 84h This is a single byte whose value is 132 do not send individual numbers 1 3 and 2 The command is...

Страница 7: ...esults the Numerical mode is more flexible TEXT Mode In the Text mode X 2071 doesn t process the mes sage in any way The first received message is placed at the leftmost position of the display and so...

Страница 8: ...pp in Koodi 1 1 2 2 3 4 4 8 If several keys are pressed simultaneously the sum of these codes is returned E g keys and the code is 4 8 C in hexadecimal When no keys is pressed the value is 0 zero The...

Страница 9: ...al RS 485 loop last unit must be terminated with 110 ohm resistor Termination can be done on terminal connections or by connecting short cut jumper into following position Fail safe ON Terminator ON F...

Страница 10: ...put thermocouple strain gage etc Additional slots Additionalcardsprovideoutput 4 20 mA alarms serial inter face BCD output etc Meter data sheet dictates possible combinations greyconnectors allowlinev...

Страница 11: ...Modular field display series 575F 1800F 6543 21 4 6 digit red LED display Power supply 85 240VACor 12 32VDC 24VAC Optioncards Alarm cards 2 relay card 4 alarm types change over contacts 3 relay card c...

Страница 12: ...12 Yritt j katu 12 Tel 358 3 342 4800 Fax 358 3 342 2066 FIN 37100 NOKIA email support nokeval com http www nokeval com Nokeval Oy...

Отзывы: