background image

Association Group Information V2

Association V2

Basic

Configuration

Device Reset Locally

Firmware Update Md V2

Indicator

Manufacturer Specific V2

Meter V4

Notification V4

Powerlevel

Protection V2

Switch Binary

Version V2

Zwaveplus Info V2

Controlled Command Classes

Application Status

Basic

Explanation of Z-Wave specific terms

Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated
wall controllers.

Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.

Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.

Inclusion — is the process of adding new Z-Wave devices into a network.

Exclusion — is the process of removing Z-Wave devices from the network.

Association — is a control relationship between a controlling device and a controlled device.

Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.

Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.

(c) 2019 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwave.eu. The template is maintained by 

Z-Wave

Europe GmbH

. The product content is maintained by 

Z-Wave Europe GmbH 

, Supportteam, [email protected]. Last update of the product data: 2017-09-04

13:21:43

Содержание NODEMSP3101

Страница 1: ...nd and origin as long as both are suited for the same frequency range If a device supports secure communication it will communicate with other devices secure as long as this device provides the same o...

Страница 2: ...nstallation 1 Plug the NodOn Micro Smart Plug on your power outlet 2 Plug the electrical appliance you want to control on the NodOn Micro Smart Plug 3 The Micro Smart Plug allows to switch ON Power ON...

Страница 3: ...ings dont work as expected 1 Make sure a device is in factory reset state before including In doubt exclude before include 2 If inclusion still fails check if both devices use the same frequency 3 Rem...

Страница 4: ...and 24 Configuration Parameters Z Wave products are supposed to work out of the box after inclusion however certain configuration can adapt the function better to user needs or unlock further enhanced...

Страница 5: ...cifications This parameter is to set the Alarm 3 Specifications Use the Home Automation Gateway interface or our Alarm set up form to define the value corresponding to your need Size 4 Byte Default Va...

Страница 6: ...ing to your need Size 2 Byte Default Value 0 Setting Description 0 65535 To set up your values please follow this link www nodon fr support msp3 alarm Parameter 20 Alarm 8 Specifications This paramete...

Страница 7: ...cro Smart Plug actions if the power Low and High Threshold are reached The value may be the sum of available values For example if you want Power High Threshold Action is enable and sent ON to Group 4...

Страница 8: ...the network It must be a controller There can be only one primary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the process of remov...

Отзывы: