0 - 65535
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
Parameter 16: Alarm 6 Specifications
This parameter is to set the Alarm 6 Specifications. Use the Home Automation Gateway interface or our Alarm set-up form to define the value
corresponding to your need.
Size: 4 Byte, Default Value: 0
Setting
Description
0 - 2097151999
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
Parameter 17: Alarm 7 Type Configuration
This parameter is to set the Alarm 7 Type. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your
need.
Size: 2 Byte, Default Value: 0
Setting
Description
0 - 2097151999
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
0 - 65535
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
Parameter 18: Alarm 7 Specifications
This parameter is to set the Alarm 7 Specifications. Use the Home Automation Gateway interface or our Alarm set-up form to define the value
corresponding to your need.
Size: 4 Byte, Default Value: 0
Setting
Description
0 - 2097151999
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
Parameter 19: Alarm 8 Type Configuration
This parameter is to set the Alarm 8 Type. Use the Home Automation Gateway interface or our Alarm set-up form to define the value corresponding to your
need.
Size: 2 Byte, Default Value: 0
Setting
Description
0 - 65535
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
Parameter 20: Alarm 8 Specifications
This parameter is to set the Alarm 8 Specifications. Use the Home Automation Gateway interface or our Alarm set-up form to define the value
corresponding to your need.
Size: 4 Byte, Default Value: 0
Setting
Description
0 - 2097151999
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
Parameter 21: Power Auto-Sending Report
This parameter will send a power report automatically if the power value changes of x % W (Watt) compared to the last report.
Size: 1 Byte, Default Value: 10
Setting
Description
0
Power Auto-Polling Report Disable
1 - 100
Power Auto-Polling Report Enable with 1% (to100%) differential
Parameter 22: Overload Report
This parameter will switch off the Micro Smart Plug in case the power is above x W (Watt) and send an alarm to the primary controller.This parameter has
the highest execution priority between all the metering configurations for security reason.
Size: 2 Byte, Default Value: 1840
Setting
Description
0
Overload Report Disable (Not Recommended)
1 - 1840
Overload Report enable with a upper limit of 1 W (to 1840 W)
Parameter 23: Energy Auto-Sending Report
This parameter will send a new energy report automatically if the energy value changes of x Wh (Watt-hour) compared to the last report.
Size: 2 Byte, Default Value: 1000
Setting
Description
0
Energy Auto-Polling Report Disable
1 - 65535
Energy Auto-Polling Report enable with 1 Wh (to 65535 Wh) diffential