background image

Copyright Statement 

Nodexon

 Networks©2020 

Nodexon

  Networks  reserves  all  copyrights  of  this  document.  Any  reproduction,  excerption,  backup,  modification, 

transmission,  translation  or  commercial  use  of  this  document  or  any  portion  of  this  document,  in  any  form  or  by  any 

means, without the prior written consent of 

Nodexon

 Networks is prohibited. 

Exemption Statement 

This document is provided “as is”. The contents of this document are subject to change without any notice. Please obtain 

the latest information through the 

Nodexon

 Networks website. 

Nodexon

 Networks endeavors to ensure content accuracy 

and will not shoulder any responsibility for losses and damages caused due to content omissions, inaccuracies or errors. 

 

Obtaining Technical Assistance

Website:https://www.nodexon.com/
Technical Support Website:https://nodexon.com/support 
Community:http://www.nodexon.com/community
Technical Support Email:[email protected]
Case Portal :https://www.nodexon.com/caseportal
Website:https://www.nodexon.com/

Содержание NX-6510S-20X4S2Q

Страница 1: ...NX 6510S 20X4S2Q Core Aggregation Switch Product Guide...

Страница 2: ...he contents of this document are subject to change without any notice Please obtain the latest information through the Nodexon Networks website Nodexon Networks endeavors to ensure content accuracy an...

Страница 3: ...https www nodexonnetworks com Technical Support Website https nodexonnetworks com support Case Portal https caseportal nodexonnetworks com Community https community nodexonnetworks com Technical Supp...

Страница 4: ...ice flow NX 6510S 20X4S2Q provides 20 10G SFP ports four 25G SFP28 ports and two 40G QSFP ports Model 100G QSFP28 Port 40G QSFP Port 25G SFP28 Port 10G SFP Port 100M 1G 2 5 G 5G 10G Ethernet Port Fan...

Страница 5: ...ly Input AC input Rated voltage 100 VAC to 240 VAC Maximum voltage 90 VAC to 264 VAC Rated frequency 50 Hz to 60 Hz Rated input current 3 A 90 264 VAC full load High voltage direct current HVDC input...

Страница 6: ...6 mm 17 32 in x 12 99 in x 1 72 in 1RU The NX 6510S 20X4S2Q switch is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to ta...

Страница 7: ...r 2 PWR1 indicator 3 PWR2 indicator 4 Fan indicator 5 MGMT port indicator 6 Locator indicator 7 MGMT port 8 SFP port indicator 9 SFP port 10 SFP28 port indicator 11 SFP28 port 12 QSFP port indicator 1...

Страница 8: ...ploading of Console ports Console port Use RS 232 interface electrical level and standard RJ45 connector This interface is connected with the serial port of terminal PC to perform system debugging con...

Страница 9: ...MGMT Off The MGMT port is NOT connected Green The MGMT port is connected Blinking green The MGMT port is transmitting or receiving data Locator indicator ID Off The locator is controlled by CPLD by d...

Страница 10: ...and asset management including model version number and SN The power module can be hot swapped and supports asset management including model version number and SN The NX 6510S 20X4S2Q switch supports...

Страница 11: ...hurting legs and feet or straining the back When the device is being removed do not hold the power supply handle or the fan handle for these parts are not designed for bearing the entire weight of th...

Страница 12: ...of all the power supplies The rated leakage non action current of a leakage protector shall be 50 of the leakage action current Take a leakage protector with 30 mA rated leakage action current as an...

Страница 13: ...install the switch inside a closed cabinet be sure that the cabinet has a good ventilation and heat dissipation system Be sure that the cabinet is firm enough to bear the weight of the NX 6510S 20X4S2...

Страница 14: ...not only affecting the service life of the device but also causing communication faults The following table shows the requirements for the dust content and granularity in the equipment room Substance...

Страница 15: ...suppression and level reference All the above constitute the comprehensive grounding requirements The grounding resistance should be less than 1 There is one grounding pole at the right bottom of the...

Страница 16: ...Tx and Rx directions of the fiber The Tx end of this device should be connected to the Rx end of the peer device and the Rx end of this device to the Tx end of the peer device 2 4 Installation Tools...

Страница 17: ...complicated device Carefully plan and arrange the installation location networking mode power supply and wiring before installation The installation location provides sufficient space for heat dissip...

Страница 18: ...net and on various boards Blank panels should be installed completely Fastening screws of various devices in the cabinet of the same model should be ready and tightened Various boards of the device sh...

Страница 19: ...lace near the cabinet where you can handle it easily Installing Mounting Brackets 1 Take out the two L shape brackets and eight M4 8FMO countersink screws from the plastic package 2 Install the bracke...

Страница 20: ...ovided are only applicable for cabinets with depth of 800mm 1200mm Mounting the Switch to a Workbench In some cases users do not have the 19 inch standard cabinet The common solution is to place the s...

Страница 21: ...th a screwdriver to fix the fan module in the switch chassis Figure 3 4 Installing a Fan Module Insert the fan module smoothly Pay attention to the direction of the fan panel to avoid wrong insertion...

Страница 22: ...ar anti static gloves before the following operations Installing a RG PA550I II F Power Module 1 Take a new power module out of the package and confirm the input mode and the input parameters of the p...

Страница 23: ...side is grooved The ring has two buckles Buckle A is used to remove the strap and buckle B is used to adjust the ring Figure 3 1 Strap Ring and Buckles 2 Insert the strap into the hole at the bottom...

Страница 24: ...d and pull out the power module uprightly and slowly 2 Install a blank panel in the power module slot and put the removed power module into its package Figure 3 10 Removing a Power Module Remove the p...

Страница 25: ...e sure that it is in good contact with the power slot Figure 3 11 Installing a Power Module Insert the power module smoothly Please pay attention to the direction of the power panel to avoid wrong ins...

Страница 26: ...d grounding should be less than 1 To guarantee the security of the person and the device the NX 6510S 20X4S2Q series switch must be well grounded The grounding resistance should be less than 1 A servi...

Страница 27: ...interface according to the identification on the panel of the line card Distinguish the crossover cable and straight through cable 3 10 Binding the Cables Precautions The power cables and other cable...

Страница 28: ...twisted pairs match the ports Verify that the cables have been bound properly Verify that the cabling specification and connecting method are correct Verify that the cablings are all indoor If any ou...

Страница 29: ...the DB 9 jack of the console cable to the serial port of the PC 2 Connect one end of the console cable RJ45 to the console port of the switch Setting Terminal Parameters Step One Start the PC and run...

Страница 30: ...tion and click OK A window appears as shown in Figure 4 3 In the column of Connect Using field select the serial port you want to use Figure 4 3 After the serial port is selected click OK The Serial P...

Страница 31: ...rectly connected Check if the power supply voltage complies with the requirement of the switch Check if the console cable is correctly connected the terminal can be a PC used for configuration is alre...

Страница 32: ...with the management software When the indicator of the host or the expansion module is red or flashing it indicates a failure in which case you need to find out the cause and turn off the power when n...

Страница 33: ...unplug the power module replace it with a qualified one and then connect the power cables Replacing Lithium Battery The built in lithium batteries can support the real time clock of the NX 6510S 20X4S...

Страница 34: ...of the switch in the cabinet Check the power connection Check the installation of the power supply module Check the plug in units of each module Check the installation and fastening of the modules Che...

Страница 35: ...ription After the system starts the fans in the fan module do not work or the Status indicator is OFF Troubleshooting Check if the connection between the fan module and the backplane is secure and if...

Страница 36: ...runs normally After the fiber interface is inserted into the optical module and the optical fiber is properly connected the link cannot be set up Troubleshooting 1 Check whether the receiving and send...

Страница 37: ...y follow TSB 155 standard requirements to ensure the reliable application of 10Gbase T The maximum transmission distance will be less than 37m when CAT6 UTP unshielded wire is exposed in severe condit...

Страница 38: ...maximum transmission distance will be less than 50m when CAT5e UTP unshielded wire is exposed in severe condition and influenced by external crosstalk The CAT5e UTP wire must meet TIA TSB 5021 require...

Страница 39: ...ta Output Transmit Data 3 Output Transmit Data Input Receive Data 6 Output Transmit Data Input Receive Data 4 5 7 8 Not Used Not Used Figure A 3 shows the feasible connections of the straight through...

Страница 40: ...f Received Light dBm min max min max MINI GBIC SX MM850 850 MMF No 9 5 3 17 0 MINI GBIC LX SM1310 1310 SMF No 9 5 3 20 3 GE eSFP SX MM850 850 MMF Yes 9 5 3 17 0 GE eSFP LX SM1310 1310 SMF Yes 9 5 3 20...

Страница 41: ...SFP LX20 SM1550 BIDI Models and Technical Specifications of the Mini GBIC GT Module Model Standard 1000Base T SFP Module 1000Base T Mini GBIC GT 1000Base T Cabling Distance 1000baseT Copper Cable Typ...

Страница 42: ...SFP 3 28 10 3125 No XG SFP CU5M Passive SFP 5 26 10 3125 No Models and Technical Specifications of the 25G SFP28 Module Model Wave length nm Optical Fiber Type Core Size m Modular Bandwidth MHz km Max...

Страница 43: ...re Diameter AWG Data Rate Gb s Support DDM Yes No 40G QSFP STACK1 M Passive QSFP 1 28 4lanes x 10 3125 No 40G QSFP STACK3 M Passive QSFP 3 28 4lanes x 10 3125 No Models and Technical Specifications of...

Страница 44: ...t Precautions for installation Make sure that the PE terminal of the power arrester has been well grounded After the switch AC power plug is connected to the socket of the power arrester lightning pro...

Страница 45: ...nding line to the grounding terminal of the switch 3 Use the multimeter to check whether the grounding line for the arrester is in good contact with the switch grounding terminal and the framework 4 A...

Страница 46: ...he IN end and connect the switch Ethernet port to the OUT end Poor arrester grounding The length of the grounding line should be as short as possible to ensure that it is in good contact with the swit...

Страница 47: ...ater than their respective diameters After cabling is fixed the bend radius of a common coaxial cable should be over seven times greater than its diameter The bend radius of this type of cables that o...

Страница 48: ...without sharp corners The metal hole traversed by cables should have a smooth and fully rounding surface or an insulated lining Proper buckles should be selected to bundle up cables It is forbidden to...

Страница 49: ...s cannot be bundled on the guide rails of moving parts The power cables connecting moving parts such as door grounding wires should be reserved with some access after assembled to avoid suffering tens...

Страница 50: ...he same cabling direction should be bundled up into cable bunches with cables in cable bunches clean and straight Binding by using buckles should be performed according to Table D 1 Cable Bunch Diamet...

Страница 51: ...orm and heavy rain as well as away from dust If the dust is unavoidable keep the door and window away from the pollution source The machine room should be away from the residential area Otherwise the...