28
new one.
Instable charge current, not
reaching the rated current
value.
①
Low power voltage.
②
Small section area of lead for
power input.
①
The power voltage may not
lower than 95% of the rated
voltage. If the voltage is too low,
please change a new power
supply.
②
The section area of input
lead of power supply may not
less than the stipulated section
area in the manual.
Air switch of the charger does
not trip, and the preceding
stage switch trips.
①
Failure of the preceding air
switch.
②
Incorrect matching of air
switch.
③
Small capacity of the air
switch.
Rated current of the preceding
stage air switch is more than
that of the air switch of the
charger.
The air switch must be type D
(dynamic type),type C
(illumination type) is
unavailable.
Excessive overcharge for the
battery.
Internal short circuit of single
battery of the group.
Check each terminal voltage of
every single battery. If some of
the voltages are lower than their
nominal voltages, the internal
polar plates suffers from short
circuit, please remove them and
change new ones.
The display signals of the
display face rolling, deadlock
and clobber.
Failure of microcomputer or
control power.
Please inform the service
engineers.
Содержание LPT22
Страница 1: ...NOBLELIFT EQUIPMENT Service Maintenance Manual LPT22 Power Pallet Truck V LPT22 01 00 Date 2011 02 26 ...
Страница 15: ...14 3 ELECTRICAL SYSTEM 3 1 ELECTRICAL DIAGRAM WIRING DIAGRAM ...
Страница 16: ...15 CONNECTION DIAGRAM ...
Страница 30: ...29 3 7 CURTIS CONTROLLER ...
Страница 63: ...62 8 2 TROUBLE SHOOT ...
Страница 64: ...63 ...