MAINTENANCE
24
Nobles Speed Scrub Orbital (12--2012)
IMPORTANT:
Before operating machine the antifreeze
must be flushed from the module as described below.
If the antifreeze is not properly flushed from the
ec--H2O
system, the
ec--H2O
module may detect an
error and not function (
ec--H2O
switch indicator light
will turn red). If this occurs, reset key and repeat the
flush procedure as described below.
Flushing antifreeze from ec--H2O module:
1. Drain the antifreeze from the solution tank into a
bucket.
2. Fill the solution tank with cool water until full (See
FILLING SOLUTION TANK).
3. Disconnect the black connector fitting at the scrub
head and place the hose into a bucket (Figure 56).
To access the connector fitting, you may have to
remove the front cover from the machine.
FIG. 56
4. Press and release the
ec--H2O
module switch to
flush the antifreeze from the
ec--H2O
system
(Figure 65). The module is located under the
recovery tank.
When the water turns clear, press the module
switch again to stop the flush cycle.
Dispose the antifreeze in an environmentally safe way
according to local waste disposal regulations.
5. The machine is now ready for scrubbing.
Содержание Speed Scrub Orbital
Страница 37: ...STANDARD PARTS Nobles Speed Scrub Orbital 12 2012 8 VACUUM MOTOR GROUP 1 5 3 9 10 11 8 7 9 4 2 1 2 11 6...
Страница 67: ...STANDARD PARTS Nobles Speed Scrub Orbital 12 2012 38 BATTERY AND CABLE GROUP 12V 155 AH 2 6 7 1 3 5 1 4...
Страница 71: ...STANDARD PARTS Nobles Speed Scrub Orbital 12 2012 42 WIRE HARNESS GROUP ec H2O OPTION 1 3 3 2...
Страница 73: ...STANDARD PARTS Nobles Speed Scrub Orbital 12 2012 44 WIRE HARNESS GROUP CONSOLE 1...
Страница 75: ...STANDARD PARTS Nobles Speed Scrub Orbital 12 2012 46 WIRE HARNESS GROUP MAIN 1 DETAIL A DETAIL B 2 3 4 4...
Страница 76: ...STANDARD PARTS Nobles Speed Scrub Orbital 12 2012 47 WIRE HARNESS GROUP MAIN CONT D 1 DETAIL A CONTINUED...
Страница 83: ...OPTIONS Nobles Speed Scrub Orbital 12 2012 54 PARKING BRAKE GROUP 1 3 4 5 6 7 8 2 9 10 3 11...