MAINTENANCE
Nobles Speed Scrub 500 (09-2020)
37
Models equipped with ec-H2O system - Turn
machine and set the solution flow rate on and
operate ec-H2O scrubbing to cycle antifreeze
through system. Turn machine off when antifreeze
is visible on the floor. This may take up to two
minutes.
5.
Models equipped with optional automatic battery
watering tank - Lift tank from machine and empty
the water from tank (Figure 97).
FIG. 97
Drain remaining water from system by removing
the drain hose cap located below the tank (Figure
98). Leave cap off tank when draining system.
After draining, replace cap on drain hose.
IMPORTANT: DO NOT add antifreeze to the
automatic battery watering tank.
FIG. 98
6.
After storing machine in freezing temperatures,
drain any remaining antifreeze from the solution
tank. Add clean water to solution tank and to
optional detergent tank and operate the machine to
flush system.
7.
Refill the automatic battery watering tank with
distilled water, if equipped.