OPERATION
Magna Twin 1600/2200/2600 (09--01)
17
TROUBLE SHOOTING
PROBLEM
CAUSE
SOLUTION
Machine does not operate.
ON/OFF switch is OFF.
Turn switch to ON.
Vacuum not plugged to wall outlet.
Plug power cord to wall outlet.
Faulty power cord.
Contact Service Center.
Faulty ON/OFF Switch.
Contact Service Center.
Faulty wiring.
Contact Service Center.
Building circuit breaker tripped.
Reset circuit breaker and change to
different power circuit.
Vacuum motor does not operate.
Sensor temperature too high.
Find air obstruction. Let motor cool
for 20 minutes.
Brush does not operate.
Brush circuit breaker tripped.
Determine what caused breaker to
trip then reset breaker.
Low suction
Vacuum bag full.
Replace bag.
Vacuum hose plugged.
Remove obstruction.
Secondary filter plugged.
See MAINTENANCE; Secondary
Filter.
Rear door gasket leakage.
Replace gasket.
Poor brush pick--up.
Brush height adjusted incorrectly.
Adjust brush height.
Clogged brush
Remove clogged material.
Worn brush bristles.
See MACHINE MAINTENANCE;
Brush and Belt.
Loose drive belt.
Inspect belt, replace if needed.