OPERATION
23
EZ Rider
t
HP 330780 (4--04)
4. Make sure to connect the supply hose onto
the hose storing plug when the supply hose
is not connected to the FaST PAK. This will
prevent the FaST solution system from
drying out and clogging up the hose.
5. The FaST solution system must be primed
for first time use only. To prime system,
make sure the solution tank is empty, and
operate the machine in the FaST Scrub
Mode for 7--10 minutes.
6. When replacing an empty FaST PAK carton,
allow the new FaST PAK detergent to
gravity feed into the system for several
minutes prior to operating the FaST system.
If the detergent does not flow out of the
FaST PAK, simply squeeze and release the
hose several times. If the previous FaST
PAK was run dry, it may take up to 7--10
minutes of operation to remove any air
pockets in the system before you achieve