OPERATION
16
Concorde
HP Plus (01–00)
SPRAY BAR AND SPRAY TIP MAINTENANCE
The spray bar can easily be removed and replaced
with a spare spray bar when spray tips require
maintenance.
TO REPLACE SPRAY BAR:
1.
Turn main power switch off.
2.
From operator’s right side of machine, locate
spray bar under machine.
3. To remove spray bar, shift spray bar to operator’s
left side of machine and pull down (Figure 35).
FIG. 35
4.
Disconnect coupler at spray bar top.
5.
Install spare spray bar, be certain to position spray
bar “FRONT” label facing forward.
TO CLEAN SPRAY TIPS:
1.
Remove clogged spray tips from spray bar. Take
note of spray tip position before removing.
2.
Pour 4 oz. of acetic acid into a small container.
3.
Completely submerge spray tips and let soak for
up to six hours. Agitate spray tips occasionally.
4.
After soaking spray tips, use small brush to
remove excess alkaline and rinse thoroughly.
ATTENTION: DO NOT use pointed objects such as
pins and paper clips to unplug spray tips. This
will damage spray tips, causing improper spray
pattern and water flow through tips.
5.
Replace spray tips in spray bar and keep on hand
for spare.
NOTE: If spray tips are damaged, replace spray tips.
Be certain to use same spray tip size and type.
Improper spray tips will affect cleaning performance.
TRANSPORTING MACHINE
When transporting machine by use of trailer or truck,
be certain to follow tie–down procedures below:
FOR SAFETY: When using machine, go slow on
inclines and slippery surfaces.
1.
Raise brush.
2.
Load machine using a recommended loading
ramp.
3.
Position front of machine up against front of trailer
or truck. Once machine is positioned, lower brush.
4.
Place a block behind the drive wheel and the rear
casters.
5.
Place tie–down straps over top of machine and
secure straps to floor. It may be necessary to
install tie–down brackets to the floor of your trailer
or truck.
STORING MACHINE
1.
Before storing machine, be certain to flush tanks
and drain machine of all water.
2.
Store machine in a dry area with the brush in the
raised position.
3.
Remove recovery tank dome to promote air
circulation.
ATTENTION: If storing machine in freezing
temperatures, be certain to drain machine of all
water. Damage due to freezing temperatures is not
covered by warranty.