OPERATION
16
Nobles SpeedGleam
/Plus (01–02)
TROUBLE SHOOTING
PROBLEM
CAUSE
SOLUTION
No Power.
Faulty main power switch.
Contact Service Center.
Faulty key switch, if equipped.
Contact Service Center.
Faulty battery(s).
Replace battery(s).
Loose battery cable.
Tighten loose cables.
Improper battery cable connection.
See Installing Batteries.
Tripped Main Power circuit breaker.
Determine cause and reset breaker.
Charger is connected.
Disconnect Battery charger.
Emergency stop button activated,
if equipped.
Turn button to reset.
Pad motor does not operate.
Faulty trigger switch(es).
Contact Service Center.
Tripped pad motor circuit breaker.
Replace pad/adjust pressure and
reset breaker. Or replace 2A fuse.
Blown fuse (2A).
Replace the 2A fuse.
Faulty contactor.
Contact Service Center.
Faulty wiring.
Contact Service Center.
Faulty pad drive motor.
Contact Service Center.
Worn carbon brushes
Contact Service Center.
Machine is tilted back on rear wheels.
Lower machine from tilt position.
Faulty tilt shut-off switch near rear
wheels.
Contact Service Center.
Drive motor does not operate or
Faulty trigger switch(es).
Contact Service Center.
operates incorrectly (Drive Model). Faulty speed control board
or connection.
Contact Service Center.
Faulty solenoid.
Contact Service Center.
Faulty drive motor.
Contact Service Center.
Faulty wiring.
Contact Service Center.
Worn carbon brushes.
Contact Service Center.
Faulty potentiometer or speed control
board.
Contact Service Center.
Loose wire connection.
Contact Service Center.
Short run time.
Low battery charge.
Charge batteries.
Defective battery cell(s).
Replace battery.
Batteries need maintenance.
See Battery Maintenance.
Faulty battery charger.
Replace charger.