OPERATION
Magna Twin
t
1600/2200/2600 (09--01)
14
TROUBLE SHOOTING
PROBLEM
CAUSE
SOLUTION
Machine does not operate.
ON/OFF switch is OFF.
Turn switch to ON.
Vacuum not plugged to wall outlet.
Plug power cord to wall outlet.
Faulty power cord.
Contact Service Center.
Faulty ON/OFF Switch.
Contact Service Center.
Faulty wiring.
Contact Service Center.
Building circuit breaker tripped.
Reset circuit breaker and change to
different power circuit.
Vacuum motor does not operate.
Sensor temperature too high.
Find air obstruction. Let motor cool
for 20 minutes.
Brush does not operate.
Brush circuit breaker tripped.
Determine what caused breaker to
trip then reset breaker.
Low suction
Vacuum bag full.
Replace bag.
Vacuum hose plugged.
Remove obstruction.
Secondary filter plugged.
See MAINTENANCE; Secondary
Filter.
Rear door gasket leakage.
Replace gasket.
Poor brush pick--up.
Brush height adjusted incorrectly.
Adjust brush height.
Clogged brush
Remove clogged material.
Worn brush bristles.
See MACHINE MAINTENANCE;
Brush and Belt.
Loose drive belt.
Inspect belt, replace if needed.
SPECIFICATIONS
MODEL
MAGNA TWIN
t
1600
MAGNA TWIN
t
2200
MAGNA TWIN
t
2600
LENGTH
480 mm (19 in)
480 mm (19 in)
480 mm (19 in)
WIDTH
400 mm (16 in)
560 mm (22 in)
660 mm (26 in)
HEIGHT
1120 mm (44 in)
1120 mm (44 in)
1120 mm (44 in)
WEIGHT
17.6Kg (38 lbs)
19.5Kg (42 lbs)
20.4Kg (44 lbs)
BRUSH MOTOR
120V, 0.125hp, 1A, 1800 rpm
120V, 0.125 hp, 1A, 1,800 rpm 120V, 0.125 hp, 1A, 1,800 rpm
220V, 0.15kW, .5A, 1800 rpm
220V, 0.15kW, .5A, 1800 rpm
220V, 0.15kW, .5A, 1800 rpm
VACUUM MOTOR
120V, 1 hp, 6.8A
120V, 1 hp, 6.8 amps
120V, 1.5 hp, 9.8 amps
POWER CORD LENGTH
15m (50 ft) Gauge--16/3
15m (50 ft) Gauge--16/3
15m (50 ft) Gauge--16/3
SWEEPING PATH
355 mm (14 in)
508 mm (20 in)
610 mm (24 in)
VACUUM BAG
10 L (.33 bushel)
10 L (.33 bushel)
10 L (.33 bushel)
DECIBEL RATING AT
OPERATOR’S EAR,
INDOORS ON CARPET
74dB(A)
74dB(A)
74dB(A)
Home
Find...
Go To..