8.
Join the second collector tightening the unions*.
9.
Tighten all screws on the base. Properly orientate the base with the collector. Firmly attach the base using 4
inserts and bolts (M8x60).
N
S
N
S
Northern Hemisphere
Southern Hemisphere
10.
Place a T-piece with the air bleed and the sensor slot at the upper left part of the collector. Connect the pipe to
the system’s heat exchanger inlet.
11.
Place a 3/4” Ø22 mechanically tightened at the collector bottom right edge.
Connect the pipe to the system’s
heat exchanger outlet.
12.
Place a Ø22 mechanically tightened copper plugs on the upper right and bottom left edge of the collector/s.
13.
Place the intermediate decorative channel (optionally), clasp the piping covers and fasten up the plugs at the
bottom part.
*Use lock nuts in order to avoid the copper tube mechanical strain.
STEP 10
STEP 11
STEP 7
STEP 12
60mm
7
.
In case of two collectors, first place the left one at the bottom part
5
, lifting the upper part
5
. Place the screws and
the collector’s fixing washers (4 for each collector) without tightening them. Place mechanically tightened Ø22
unions at the edges of the collector.