Buffer Water Tanks

MODEL

400lt

Ø700

500lt

Ø700

800lt

Ø990

1000lt

Ø990

Capacity

Lt

379

444

763

955

Net weight

kg

126

164

195

225

Insulation

mm

50

50

100

100

Heat Exchanger surface C1

1,65

2,06

2,45

3,18

Heat Exchanger surface C2

0,97

0,96

1,46

1,49

Heat Exchanger capacity C1

Lt

10,21

12,44

20,11

26,00

Heat Exchanger capacity C2

Lt

5,87

6,06

11,96

12,17

Heat Exchanger output (60-80°C) C1

kW

45

52

57

78

Heat Exchanger output (60-80°C) C2

kW

25

31

39

33

DHW Continuous flow rate (60-80°C) C1

L/h

1106

1278

1401

1917

DHW Continuous flow rate (60-80°C) C2

L/h

614

762

958

811

Heat losses ∆T 45K

kWh/24h

2,3

2,4

4,1

4,5

Energy efficiency class

C

C

C

C

Maximum operational temperature

0

C

95

95

95

95

Rated pressure

bar

3

3

3

3

Rated pressure of the heat exchanger

bar

6

6

6

6

NL factor C1

12,5

19

26

35

NL factor C2

2,3

3,2

10

16

MODEL

400lt

Ø700

500lt

 Ø700

800lt

Ø990

1000lt

Ø990

External Diameter

D ext

mm

700

700

990

990

Internal Diameter

D int

mm

600

600

850

850

Height

HT

mm

1655

1900

1770

2100

Lower HE outlet

C

mm

238

238

331

331

Lower HE Inlet

D

mm

778

913

878

1046

Upper HE outlet

E

mm

938

1073

1025

1262

Upper HE Inlet

F

mm

1253

1388

1375

1612

Sensor pocket 1

G

mm

508

576

606

689

Sensor pocket 2

H

mm

1096

1231

1200

1437

Thermo Level

Q1

mm

239

239

331

331

Thermo Level

Q2

mm

628

712

678

797

Thermo Level

Q3

mm

1018

1184

1025

1262

Thermo Level

Q4

mm

1407

1656

1372

1727

Sensor Level

P1

mm

239

239

331

331

Sensor Level

P2

mm

628

712

678

797

Sensor Level

P3

mm

1018

1184

1025

1262

Sensor Level

P4

mm

1407

1656

1372

1727

Thermometer

L

mm

1407

1656

1372

1727

160lt-500lt

800lt-1000lt

Lower HE outlet

C

F 1"

F 1 1/2"

Lower HE Inlet

D

F 1"

F 1 1/2"

Upper HE outlet

E

F 1"

F 1 1/2"

Upper HE Inlet

F

F 1"

F 1 1/2"

Sensor pocket 1

G

F 1/2"

F 1/2"

Sensor pocket 2

H

F 1/2"

F 1/2"

Thermo Level

Q1-4

F 1 1/2"

F 1 1/2"

Sensor Level

P1-4

F 1/2"

F 1/2"

Air ventilation

Av

F 1 1/2"

F 1 1/2"

Thermometer

L

F 1/2"

F 1/2"

Buffer Water Tanks   -  

DOUBLE HEAT ExCHANGER (BF 2)

Содержание 1000lt

Страница 1: ...Installation maintenance use instructions Buffer Water Tanks 160 1000 lt Technical Manual...

Страница 2: ......

Страница 3: ...ger BF2 11 GENERAL INSTALLATION RULES 12 INSTALLATION POSITION 13 GENERAL PREVENTION MEASURES 14 INSTRUCTIONS FOR THE INTERCONNECTION OF COLLECTORS IN SOLAR FIELDS 15 RECOMMENDATIONS ON HEAT TRANSFER...

Страница 4: ...imum use of hot water should be made during daytime so that the system can continuously produce hot water during the daylight hours maintaining thus its maximum efficiency SOLAR WATER HEATING The coll...

Страница 5: ...rbon dioxide emissions are reduced Central solar systems are made of excellent materials according to international specifications and have all the certificates and tests that attest their quality The...

Страница 6: ...e following table PACKAGING 1 Buffer 2 Collector s 3 Support base fittings Accessories 4 Hydraulic Unit 5 Palette 1 2 2 3 4 5 FITTINGS ACCESSORIES FITTING ACCESSORIES FOR COLLECTORS KIT FOR FC BUFFER...

Страница 7: ...are important for the future identification of the product When applied Capacity xxx lt Weight xxx kg Max working pressure xxx bar Max working temperature xxx C Lower heat exchanger surface S1 xxx m2...

Страница 8: ...onal internal coil type heavy duty steel type Tubo integrated in the upper part of the buffer tank for the connection of the secondary heating source y y Thermal insulation which minimises heat losses...

Страница 9: ...243 243 239 239 331 331 Sensor Level P2 mm 424 489 666 628 712 678 797 Sensor Level P3 mm 605 735 1088 1018 1184 1025 1262 Sensor Level P4 mm 786 981 1511 1407 1656 1372 1727 Thermometer L mm 786 981...

Страница 10: ...ernal Diameter D ext mm 600 600 600 700 700 990 990 Internal Diameter D int mm 500 500 500 600 600 850 850 Height HT mm 1035 1230 1760 1655 1900 1770 2100 Lower HE Outlet C mm 242 242 242 238 238 331...

Страница 11: ...990 External Diameter D ext mm 700 700 990 990 Internal Diameter D int mm 600 600 850 850 Height HT mm 1655 1900 1770 2100 Lower HE Outlet C mm 238 238 331 331 Lower HE Inlet D mm 778 913 878 1046 Up...

Страница 12: ...ION RULES ATTENTION Installation must be in compliance with local national rules concerning water and electrical installations plumbing electricity hygiene urban and others The solar system s packagin...

Страница 13: ...t may be the result of an inappropriate installation or incorrect use of components used for the solar water heater installation INSTALLATION POSITION The installation is only allowed on roofs and fla...

Страница 14: ...al systems can only be undertaken by authorized specialized companies and trained personnel y y Works in electrical installations or conductors have to be executed by trained specialized electro techn...

Страница 15: ...when the internal temperature reaches 4 C Additionally under no circumstances must the automatic filling valve be left open as there is the danger that if the collector bank has a small leak at some...

Страница 16: ...c building sanitary etc in force y y It is recommended to place a vessel under the hydraulic unit of a capacity suitable to collect the anti freeze liquid that may run from the security valve The pres...

Страница 17: ...stant to high temperatures and suitable for solar installations Insulating material Thread according to DIN 2999 ISO 7 and ISO 228 standards Measurement accuracy 10 from the final value Anti freeze li...

Страница 18: ...pump ca be replaced without having to empty the system using the stop cocks on the suction side Setter Inline PF and the pressure side ball valve 7 8 BALL VALVE FOR THE EASY FILLING AND EMPTYING OF T...

Страница 19: ...the position V 6 Connect the evacuation pipeline of the safety valve to the position VI of the hydraulic unit NOTE The safety valve should have a drain pipe connected to its outlet This pipe should r...

Страница 20: ...is washed at an hour of low sunlight to avoid damages due to expansion contraction due to temperature changes y y If the fittings are worn screws pugs piping etc these should be replaced at the owner...

Страница 21: ...insulated Has the installment on the roof been done according to the local regulations HYDRAULIC CONNECTIONS Are there any leaks in the closed circuit the connections or in the tube heat exchanger Ar...

Страница 22: ...22 NOTES...

Страница 23: ...23 Buffer Water Tanks...

Страница 24: ...uffer Water Tanks 160 1000 lt NOBEL INTERNATIONAL EAD SOLAR WATER HEATING SYSTEMS INDUSTRY 48 Vitosha Blvd Elin Pelin 2100 Sofia Region Bulgaria Tel 359 2 4210232 email info nobel bg www nobel bg Inst...

Отзывы: