Fan speed button (SPEED) 

By pressing this button you switch between low (LOW) and high (HIGH) fan speeds. At the same time, a diode 
will light up on the control panel beside the relevant speed. This option to change speeds is switched off in the 
dehumidification (DEHUM) and sleep (SLEEP) modes.

 

 

Sleep mode button (SLEEP)

 

In the cooling (COOL) mode you can select sleep mode. Because of the lower noise level the fan runs at a lower 
speed and during the first two hours of the target temperature will be automatically raised by one degree 
Celsius every hour.

 

 

Dehumidification button (DEHUM) and connection of the hose

 

The air conditioner will operate at the lower fan revolutions and dry out the air in the room, provided room 
temperature remains above 15°C. In this mode it is not possible to set a required temperature or change the 
fan speed. If the room temperature is lower than 15°C, the compressor will switch itself off and 
dehumidification will stop.

 

In this mode it is necessary to attach the hose for releasing water – remove the plug from the lower part of the 
appliance and attach the hose with a 16 mm diameter

 

(included in the pack). The other end of the hose should 

either drain into a suitable vessel or directly to a drain. The hose should be set at the minimum incline in order 
for the condensate to drain out properly.

 

Once dehumidification is complete, disconnect the hose from the machine and – with a gentle tipping motion 
towards the outflow – pour out the remaining water from the air conditioner (it is a good idea to place a 
shallow vessel or plate below the outflow); finally, replace the plug onto to the outflow. 
Switch off the dehumidification mode by changing to another mode using the MODE button.

 

Remote control 

 

   

 

 

 

 

 

 

 

 

 

 

Decreasing 
temperature/timer value

 

Increasing temperature/timer 
value

 

Sleep mode

 

Change of fan speed

 

Choice of mode 
(MODE)

 

Two-way timer 
(to set a delayed start or 
switch-off, see the section 

Timer button

)

 

Switch the 
appliance on/off 

 

Содержание AC 5109

Страница 1: ...INSTRUCTIONS Noaton AC 5109 Local air conditioner ...

Страница 2: ... disposed of with other household waste but must be taken to a collection point designated for recycling electrical appliances This product complies with valid EU and other regulations The product uses flammable refrigerant There is a risk of fire if refrigerant escapes from the appliance and comes into contact with an open flame or other strong heat source ...

Страница 3: ...utton MODE 8 Timer button TIMER 8 Fan speed button SPEED 9 Sleep mode button SLEEP 9 Dehumidification button DEHUM and connection of the hose 9 Remote control 9 Overview of modes 10 Cooling mode COOL 10 SMART mode 10 Fan mode FAN 10 Package contents 11 Connecting the air hose and the adapter 11 Increase the efficiency of mobile air conditioning 12 Cleaning and storage 12 Error messages on the disp...

Страница 4: ...ct against other objects or people Unsuitable handling may damage the appliance s components or electrical connection and may therefore result in conditions that may cause risk Operate on a stable surface Always operate the appliance on a stable level surface e g on the floor so that the air conditioner is unable to fall and cause an injury or be damaged Keep away from water Never use the applianc...

Страница 5: ...e concentration rises most at ground level but it can swirl eg through draft fan etc into higher layers The propane used in this device is an odourless gas Do not use the device in the rooms with in an open fire or other strong heat sources such as cigarettes candles etc or electrical discharges Place the unit in a room that can be ventilated and where gas accumulation is not possible If propane i...

Страница 6: ...in spaces that have been well sealed so that there is as little heat intake from sunlight as possible Leave doors closed draw the curtains blinds and if possible try and cool the room before using it This procedure is especially suitable with e g bedrooms which should be cooled in advance before going to bed in order to avoid having to keep the air conditioner running overnight Technical specifica...

Страница 7: ...7 Product description Front Rear Control panel Remote control signal receptor Air outflow Handle Air suction Cable storage Connecting the air hose Drain with plug ...

Страница 8: ...ilable modes COOL SMART FAN Timer button TIMER If the air conditioner is in standby mode using the timer button and the and buttons you can set an interval between 1 and 24 hours after which the appliance will switch itself on The appliance display will show the remaining time until it starts up in hours Note always rounded up to the nearest whole hour so if e g there is 1 h and 15 min until the s...

Страница 9: ... the compressor will switch itself off and dehumidification will stop In this mode it is necessary to attach the hose for releasing water remove the plug from the lower part of the appliance and attach the hose with a 16 mm diameter included in the pack The other end of the hose should either drain into a suitable vessel or directly to a drain The hose should be set at the minimum incline in order...

Страница 10: ... protect the compressor Cooling does not work at temperatures under 15 C or above 43 C SMART mode In the 22 24 C range or below the unit only uses the fan above that threshold temperature the cooling circuit of the appliance is activated and therefore the air conditioner works in cooling mode In this mode it is not possible set the required target temperature although the fan speed can be adjusted...

Страница 11: ...11 Package contents 1 Hose 4 Remote control 2 Hose adapter 5 Outflow hose 3 Hose end piece Connecting the air hose and the adapter ...

Страница 12: ...he socket Clean the appliance using a soft dry cloth Prevent any water from penetrating into the machine Do not use any chemical agents or abrasive preparations on the surface of the appliance The filter can be vacuum cleaned or washed in warm soapy water Make sure it is completely dry before reinstallation The filter should be checked once a week Before relocating the air conditioner or moving it...

Страница 13: ...t In this case it is necessary to check whether the cable from the main control board has become detached alternatively the control board and or display may need replacing Such actions must only be performed by a authorized technician Please contact your local distributor E1 Temperature sensor fault The temperature sensor needs replacing Please contact your local distributor E2 Evaporator coils se...

Страница 14: ...ioner unit on a level surface Too loud in the bedroom Cool the room in advance Start the air conditioner several hours before you go to bed and make sure curtains and doors are shut so that the room is cool before sleep Cannot change fan speed Appliance is in dehumidification or sleep mode Change the appliance mode if required MODE button Cooling is not effective Room is too big Check whether cool...

Страница 15: ...igerant fluid would be leaked to the atmosphere the impact on global warming would be 3 times higher than 1 kg of CO2 over a period of 100 years Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional ENERGY EFFICIENCY CLASS A Energy consumption 1 00 kWh per 60 minutes based on standard test results Actual energy consumption wi...

Страница 16: ...16 ...

Отзывы: