Notes related to R290 refrigerant  

 

This  equipment  is  only  designed  for  use  with  R290  (propane)  refrigerant,  which  is  sealed  in  the 
refrigerant circuit under pressure. Repairs to this equipment may only be carried out by a specially 
trained service technician in accordance with national legislation on flammable substances! Do not 
manipulate with the cooling circuit, puncture it, or expose it to higher temperatures. 

Do not discharge the refrigerant into the atmosphere. 

Do not attempt to accelerate the defrosting process in any way (for example, by heating). 

The device must be placed in a room of at least 10 m

2

R290 is a flammable gas (propane) and is heavier than air. For this reason, its leakage concentration 
rises most at ground level, but it can swirl (eg through draft, fan, etc.) into higher layers. The propane 
used in this device is an odourless gas. 

Do  not  use  the  device  in  the  rooms  with  in  an  open  fire  or  other  strong  heat  sources  (such  as 
cigarettes, candles, etc.) or electrical discharges. Place the unit in a room that can be ventilated and 
where gas accumulation is not possible. 

If propane is detected in the room or is suspected to be present, do not allow unauthorized persons 
to  locate  the  leak.  In  this  case,  evacuate  all  people  from  the  room,  open  the  windows,  leave  the 
room and notify the local fire station of the propane leak. Do not allow any person to return to the 
room  until  the  fire  brigade  commander  or  a  certified  service  technician  decides  that  the  danger  is 
over. 

FAILURE TO COMPLY WITH THE ABOVE GUIDELINES MAY RESULT IN FIRE, EXPLOSION, PROPERTY 
DAMAGE, INJURY OR DEATH. 

 

 

 

 

 

 

Содержание AC 5109

Страница 1: ...INSTRUCTIONS Noaton AC 5109 Local air conditioner ...

Страница 2: ... disposed of with other household waste but must be taken to a collection point designated for recycling electrical appliances This product complies with valid EU and other regulations The product uses flammable refrigerant There is a risk of fire if refrigerant escapes from the appliance and comes into contact with an open flame or other strong heat source ...

Страница 3: ...utton MODE 8 Timer button TIMER 8 Fan speed button SPEED 9 Sleep mode button SLEEP 9 Dehumidification button DEHUM and connection of the hose 9 Remote control 9 Overview of modes 10 Cooling mode COOL 10 SMART mode 10 Fan mode FAN 10 Package contents 11 Connecting the air hose and the adapter 11 Increase the efficiency of mobile air conditioning 12 Cleaning and storage 12 Error messages on the disp...

Страница 4: ...ct against other objects or people Unsuitable handling may damage the appliance s components or electrical connection and may therefore result in conditions that may cause risk Operate on a stable surface Always operate the appliance on a stable level surface e g on the floor so that the air conditioner is unable to fall and cause an injury or be damaged Keep away from water Never use the applianc...

Страница 5: ...e concentration rises most at ground level but it can swirl eg through draft fan etc into higher layers The propane used in this device is an odourless gas Do not use the device in the rooms with in an open fire or other strong heat sources such as cigarettes candles etc or electrical discharges Place the unit in a room that can be ventilated and where gas accumulation is not possible If propane i...

Страница 6: ...in spaces that have been well sealed so that there is as little heat intake from sunlight as possible Leave doors closed draw the curtains blinds and if possible try and cool the room before using it This procedure is especially suitable with e g bedrooms which should be cooled in advance before going to bed in order to avoid having to keep the air conditioner running overnight Technical specifica...

Страница 7: ...7 Product description Front Rear Control panel Remote control signal receptor Air outflow Handle Air suction Cable storage Connecting the air hose Drain with plug ...

Страница 8: ...ilable modes COOL SMART FAN Timer button TIMER If the air conditioner is in standby mode using the timer button and the and buttons you can set an interval between 1 and 24 hours after which the appliance will switch itself on The appliance display will show the remaining time until it starts up in hours Note always rounded up to the nearest whole hour so if e g there is 1 h and 15 min until the s...

Страница 9: ... the compressor will switch itself off and dehumidification will stop In this mode it is necessary to attach the hose for releasing water remove the plug from the lower part of the appliance and attach the hose with a 16 mm diameter included in the pack The other end of the hose should either drain into a suitable vessel or directly to a drain The hose should be set at the minimum incline in order...

Страница 10: ... protect the compressor Cooling does not work at temperatures under 15 C or above 43 C SMART mode In the 22 24 C range or below the unit only uses the fan above that threshold temperature the cooling circuit of the appliance is activated and therefore the air conditioner works in cooling mode In this mode it is not possible set the required target temperature although the fan speed can be adjusted...

Страница 11: ...11 Package contents 1 Hose 4 Remote control 2 Hose adapter 5 Outflow hose 3 Hose end piece Connecting the air hose and the adapter ...

Страница 12: ...he socket Clean the appliance using a soft dry cloth Prevent any water from penetrating into the machine Do not use any chemical agents or abrasive preparations on the surface of the appliance The filter can be vacuum cleaned or washed in warm soapy water Make sure it is completely dry before reinstallation The filter should be checked once a week Before relocating the air conditioner or moving it...

Страница 13: ...t In this case it is necessary to check whether the cable from the main control board has become detached alternatively the control board and or display may need replacing Such actions must only be performed by a authorized technician Please contact your local distributor E1 Temperature sensor fault The temperature sensor needs replacing Please contact your local distributor E2 Evaporator coils se...

Страница 14: ...ioner unit on a level surface Too loud in the bedroom Cool the room in advance Start the air conditioner several hours before you go to bed and make sure curtains and doors are shut so that the room is cool before sleep Cannot change fan speed Appliance is in dehumidification or sleep mode Change the appliance mode if required MODE button Cooling is not effective Room is too big Check whether cool...

Страница 15: ...igerant fluid would be leaked to the atmosphere the impact on global warming would be 3 times higher than 1 kg of CO2 over a period of 100 years Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional ENERGY EFFICIENCY CLASS A Energy consumption 1 00 kWh per 60 minutes based on standard test results Actual energy consumption wi...

Страница 16: ...16 ...