CONNECTIONS
CONNECTIONS
Typical AS/400 Installation
AS/400 TWINAX Brick Detail
A major difference between the newer AS/400 work station controllers
GXM
AS/400
PATCH
PANEL
STARS
62.5 micron multimode
UTP cabling
WALL
PLATE
Balun & T cable
8 Port Twinax Brick
ASF Baluns. See
below for
GXM
0
1
2
3
7
6
5
4
PORT & POLLING GROUP ASSIGNMENTS
ON THE TWINAX BRICK FOR THE NEW AS/400 WSC
WITH SPLIT POLLING FEATURE
ASF BALUN
ASF BALUN
ASF BALUN
ASF BALUN
ASF BALUN
ASF BALUN
ASF BALUN
ASF BALUN
TO AS/400 WSC
TO GXM
PORT# 0
PORT# 1
PORT# 2
PORT# 3
TO GXM
PORT# 4
PORT# 5
PORT# 6
PORT# 7
POLLING GROUP# 1
POLLING GROUP# 2
FRONT VIEW
GXM
GXM
AS/400
PATCH
PANEL
STAR
62.5 micron multimode
UTP cabling
WALL
PLATE
Balun & T cable
DB25 to DB25
STP CABLE