EXTENSION CABLE
If an extension cable is required, it must have a sufficient cross-section so as to prevent an excessive
drop in voltage or overheating. An excessive drop in voltage reduces the output and can lead to failure
of the motor. The following table shows you the correct cable diameter as a function of the cable length
for this machine. Use only U.L. and CSA listed extension cables. Never use two extension cables
together. Instead, use one long one.
Total Extension
Cord Size (AWG)
Cord Length (feet)
25
16
50
12
100
10
150
8
200
6
UNPACKING
Carefully remove the tool and all loose items from the shipping container.
Retain all packing materials until after you have inspected and satisfactorily operated the machine.
CARTON CONTENTS
1.
M3 L-hex Wrench
2.
M8 L-hex Wrench
3.
M24 x 27 Double Open-End Wrench
4.
M22 Open-End Wrench
5.
M32 Open-End Wrench
DO NOT OPERATE THIS TOOL UNTIL YOU READ AND UNDERSTAND THE ENTIRE
INSTRUCTION MANUAL.
SETTING THE CHAMFER HEIGHT
DISCONNECT TOOL FROM POWER SOURCE.
Loosen the 2 Depth lock screws of both sides with supplied M8 Hex. Wrench.
Turn the Depth adjustor knob clockwise or counter-clockwise to adjust to the desired
chamfering height. Please refer to the scale on the side of the machine, maximum chamfering
depth up to 12mm at 45 deg.
After making sure the chamfering blades are set to the desired height, fasten the 2 Depth lock
screws.
Depth lock screw
Chamfer height scale